Satronic Relay GF 2 TV10/TS10

Satronic Relay GF 2 TV10/TS10 is an automatic oil burner control unit for combustion systems handling fuel throughput up to 100 kg/h. Operating at 220-240V~ 50/60Hz and meeting DIN EN 230:2005 and DIN EN…

SKU 3G-CBM-05973

Also listed as: REL 40107 · REL-40107

Brand
Satronic
Item
Relay GF 2 TV10/TS10
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Satronic
type
Automatic oil burner control
standards
DIN EN 230:2005, DIN EN 13842:2004-10
supply voltage
220-240V~, 50/60Hz
fuel throughput
<30 kg/h (TSMAX=10s) or 30-100 kg/h (TVmin=15s, TSMAX=5s)

Datasheet Content

APPLICATION EURO-OIL CONTROLS This range of electronic oil burner controls has been specifically designed for oil burners for non permanent operation. SERIES 10 The automatic burner controls of this series are suitable for: − monobloc oil burners; AUTOMATIC OIL BURNER CONTROL − power washers; SYSTEM − warm air generators; − steam boilers; − kilns. Due to the technical and structural characteristics and to the variety of models they can be used for the automation of cookers and oil burner operated appliances for domestic and industrial applications. FEATURES Table 1 shows the main features of this series. Other important features are: − for non permanent operation; − for fuel throughput < 30 kg/h (TSMAX = 10s) or fuel throughput from 30 to 100 kg/h (TVmin = 15s e TSMAX = 5s); − in accordance with the European standard concerning monobloc oil burners and control systems DIN EN 230:2005; − in compliance also with the standard DIN EN 13842:2004-10 for warm air generators (WLE, versions with TV = 20s e TS = 5s); − two independent safety contacts for oil valve control; − electrical service life at max load >250.000 operations; − simple wiring and installation. Table 1 Classification code according to EN 230 Normal operation in case of pre-heating Flame detectors thermostat opening External remote reset Flame detectors Single flame Dual flame Pre-heater On-board reset FC11/* FC13/* FC14/* FC14L/* Certificate N°. Type FC7/* FC8/* GR1 * (1) * * * FMCLXN 09 07 91305 002 GR1/Z * * * * * * FMCLXN 09 07 91305 002 GR2 * (1) * * * FTCLXN 09 07 91305 003 G22 * (1) * * FMCLXN 09 07 91305 001 G22/Z * * * * * FMCLXN 09 07 91305 001 GF2 * * * FTCLXN 09 07 91305 001 OR1 * (1) * * FMCLXN 09 07 91305 002 OR1/Z * * * * * FMCLXN 09 07 91305 002 OR2 * * * FTCLXN 09 07 91305 003 OR3/B * * * * FTCLXN 09 07 91305 003 NOTE: 1. this option is possible only by an external connection. 14710_r01 1/6 TECHNICAL DATA OVERALL DIMENSIONS Supply voltage: 220÷240V∼ @ 50/60Hz The following figure (Fig.1) shows the overall dimensions of On request: 110÷120V∼ @ 50/60Hz the control. Operating temperature range: -20°C ÷ +60°C Ambient humidity: 95% max @ 40°C Protection degree: IP 40 Times: 1 - Prepurge time (TV) : 1,5 / 10 / 20 / 30 / 40 s 1 - Safety time (TS) : 5 / 10 s - Dropout time on running flame failure: <1s Power consumption: - for supply voltage of 220÷240VAC: 8 VA - for supply voltage of 110÷120VAC: 4 VA Contact rating: Imax - Room thermostat (T): 5,0 A cosϕ > 0,4 2 - Pre-heater thermostat (TC) : 4,5 A cosϕ > 0,4 - Pre-heater (RISC): 0,5 A cosϕ = 1,0 - Fan (MB): 2,0 A cosϕ > 0,4 - Ignition transformer (TR): 2,0 A cosϕ > 0,4 - First valve (EV1): 0,5 A cosϕ > 0,4 Fig. 1 – Overall dimensions - Second valve (EV2): 0,5 A cosϕ > 0,4 - Alarm (SB): 1,0 A cosϕ = 1,0 CONNECTION Maximum length of external components cables: For the connection of the external components the control - Thermostats (T - TC): 20 m can be fitted either with socket type N (see Fig. 2), provided - Reset and alarm (RE - SB): 10 m with a screw terminal board which allows a simple and safety - All the others: 1m connection. 3 To fix the sockets it is advisable to use screws type M4. To Switch-off voltage :…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Satronic Relay GF 2 TV10/TS10 is an automatic oil burner control unit for combustion systems handling fuel throughput up to 100 kg/h. Operating at 220-240V~ 50/60Hz and meeting DIN EN 230:2005 and DIN EN 13842:2004-10 standards, it integrates into industrial heating and boiler applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Satronic GF 2 TV10/TS10 burner control in the Philippines?

Order from 3G Electric Philippines. We deliver to Manila, Quezon City, and across the CALABARZON region. 3G Electric handles all Bureau of Customs documentation, logistics, and PHP invoicing. Lead time on request.

What fuel throughput does the Satronic GF 2 TV10/TS10 handle?

The relay manages up to 100 kg/h fuel throughput. For <30 kg/h operation, use TSMAX setting of 10 seconds. For 30–100 kg/h, set TVmin to 15 seconds and TSMAX to 5 seconds.

What are the electrical specifications and standards for this burner control?

Supply voltage is 220–240V~ at 50/60Hz. The unit meets DIN EN 230:2005 and DIN EN 13842:2004-10 standards for automatic oil burner controls, ensuring compliance in industrial heating and boiler applications.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay GF2 S10
Satronic
Satronic
Relay TF 844
Satronic
Satronic
Relay CM 32 TW20/TS10
Satronic
Satronic
Relay SM 592.2 TW5/TS10
Satronic
Satronic
Relay VM44G TV30 TS3
Satronic
Satronic
Relay G22 S09

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)