We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
CBMMeasurement & Detection

CBM Automatic TRMS multimeter MM720 (replaces MM2000)

The CBM MM720 is an automatic-ranging digital multimeter for electrical troubleshooting and maintenance. It delivers True RMS measurement accuracy with Low Impedance mode and audible continuity testing. Ideal for…

SKU 3G-CBM-04579

Also listed as: MES 40010 · MES-40010

Brand
CBM
Item
Automatic TRMS multimeter MM720
Category
Measurement & Detection
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

CBM
type
Auto-Ranging Digital Multimeter
features
Data Hold, Range Hold, Low Impedance, Audible Continuity, Min/Max/Relative
standards
UL 61010-1, 61010-2-030, 61010-2-033; CSA C22.2 #61010-1
calibration
1 year
measurement
True RMS

Datasheet Content

ENGLISH MM700 INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology • DATA & RANGE HOLD • LOW IMPEDANCE • AUDIBLE CONTINUITY • MIN / MAX / RELATIVE • TEMPERATURE • DIODE TEST • CAPACITANCE & FREQUENCY 1000V 10A 40M Ω ESPAÑOL pg. 19 FRANÇAIS pg. 37 ENGLISH GENERAL SPECIFICATIONS Klein Tools MM700 is an automatically ranging true root mean square (TRMS) digital multimeter that measures AC/DC voltage, AC/DC current, and resistance. It can also measure temperature, capacitance, frequency, duty-cycle, test diodes and continuity. • Operating Altitude: 6562 ft. (2000m) • Relative Humidity: <90% non-condensing • Operating Temp: 14°F to 122°F (-10°C to 50°C) • Storage Temp: -4°F to 140°F (-30°C to 60°C) • Accuracy: Values stated at 65°F to 83°F (18°C to 28°C) • Temp Coefficient: 0.1 x (Quoted Accuracy) per °C above 28°C or below 18°C, corrections are required when ambient working temp is outside of Accuracy Temp range • Dimensions: 7.02" x 3.54" x 2.10" (178.3 x 89.9 x 53.3 mm) • Weight: 14.6 oz. (414 g) • Calibration: Accurate for one year • Standards: Conforms to: UL STD 61010-1, 61010-2-030, 61010-2-033. Certified to: CSA STD C22.2 # 61010-1, 61010-2-030, 61010-2-033. IEC EN 61010-1, 61010-2-030, 61010-2-033, 61326-1. • Pollution degree: 2 • Accuracy: ± (% of reading + # of least significant digits) • Drop Protection: 6.6 ft. (2m) • Ingress Protection: IP42 (except test lead jacks, see WARNINGS) • Safety Rating: CAT IV 600V, CAT III 1000V, Class 2, Double insulation CAT III: Measurement category III is applicable to test and measuring circuits connected to the distribution part of the building’s low-voltage MAINS installation. CAT IV: Measurement category IV is applicable to test and measuring circuits connected at the source of the building’s low-voltage MAINS installation. • Electromagnetic Environment: IEC EN 61326-1. This equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations. Specifications subject to change. 2 ELECTRICAL SPECIFICATIONS VOLTAGE (AUTO-RANGING) Function Range Resolution Accuracy (50–60 Hz) 4.000V 1mV ±(1.0% + 5 digits) AC Voltage 40.00V 10mV ±(1.2% + 5 digits) (V AC) 400.0V 100mV ±(1.5% + 5 digits) 1000V 1V 400.0mV 0.1mV ±(1.0% + 8 digits) 4.000V 1mV DC Voltage 40.00V 10mV ±(1.0% + 3 digits) (V DC) 400.0V 100mV 1000V 1V ±(1.2% + 3 digits) Input Impedance: 10MΩ Frequency Range: 50 to 400Hz Maximum Input: 1000V AC RMS or 1000V DC CURRENT (AUTO-RANGING) 400.0μA 0.1μA 4000μA 1μA AC Current ±(1.5% + 3 digits) 40.00mA 10μA (μA and mA) 400.0mA 100μA 10.00A 0.01A ±(2.0% + 5 digits) 400.0μA 0.1μA 4000μA 1μA DC Current ±(1.0% + 3 digits) 40.00mA 10μA (μA and mA) 400.0mA 100μA 10.00A 0.01A ±(1.5% + 3 digits) Overload Protection: 500mA / 1000V and 10A / 1000V Fuses Frequency Range: 50 to 400Hz Maximum Input: µA/mA setting: 400mA AC RMS / DC 10A setting: 10A AC RMS / DC RESISTANCE (AUTO-RANGING) Function Resolution Accuracy 400.0Ω 0.1Ω 4.000kΩ 1Ω ±(1.5% + 5 digits) 40.00kΩ 10Ω 400.0kΩ 100Ω 4.000MΩ 1kΩ ±(2.0% + 10 digits) 40.00MΩ 10kΩ Maximum Input: 600V DC or 600V AC RMS 3 ENGLISH ELECTRICAL SPECIFICATIONS CAPACITANCE (AUTO-RANGING) Range Resolution Accuracy 40.00nF 10pF ±(5.0% + 35 digits) 400.0nF 0.1nF 4.000μF 1nF ±(3.0% + 5 digits) 40.00μF 10nF 400.0μF 100nF 4000μF 1μF ±(5.0% + 5 digits) Maximum Input: 600V DC or 600V AC RMS FREQUENCY (AUTO-RANGING) 9.999Hz 0.001Hz 99.99Hz 0.01Hz 999.9Hz 0.1Hz ±(1.0% + 5 digits) 9.999kHz 1Hz 99.99kHz 10Hz 500.0kHz 100Hz Sensitivity: >8V RMS Maximum Input: 600V DC or 600V AC RMS DUTY CYCLE 1% to 99.9% 0.1% ±(1.2% + 2 digits) Pulse width: 0.1 – 100ms Frequency width: 5Hz to 10kHz Sensitivity: >8V RMS Maximum Input: 600V DC or 600V AC RMS TEMPERATURE 0° to 1500°F 0.1°F / 1°F ±(2.0% + 9°F) -18° to 816°C 0.1°C / 1°C ±(2.0% + 5°C) 4 ELECTRICAL SPECIFICATIONS OTHER MEASUREMENT APPLICATIONS Maximum Input: 100V RMS in Voltage setting, 600V DC or 600V AC RMS in all other settings • Diode Test: 1.5 mA max, open circuit voltage 3.0V DC • Continuity Check: Audible signal when resistance <50Ω, max test current 0.35mA • Low Impedence (Low Z): Input impedence >3kΩ Max input 600V RMS • Auto Power off: After ~30 minutes of inactivity • Sampling Frequency: 3 samples per second • Bar Graph: 41 segment, 10-15 samples per second • Overload: "OL" indicated on display, 1000V RMS in voltage settings, 600V RMS in all other settings • Polarity: "-" on display indicates negative polarity • Display: 3 ¾ digit, 4000 Count LCD, TRMS technology WARNINGS To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death. • Before each use verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use the meter during electrical storms or in wet weather. • Do not use the meter or test leads if they appear to be damaged. • Use only with CAT IV rated test leads. • Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. • Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages pose a shock hazard. • To avoid false readings that can lead to electrical shock, replace batteries when a low battery indicator appears. • Do not attempt to measure resistance or continuity on a live circuit. • Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. • Meter is IP42 dust & water resistant. Following any contact with water, thoroughly dry meter and test lead jacks prior to subsequent use. 5 ENGLISH SYMBOLS ON METER AC/DC Voltage or Current Resistance (in Ohms) Audible Continuity Diode Capacitance Hz Frequency % Duty-cycle Double Insulated Class II °F/°C Temperature (Fahrenheit / Celsius) Ground Fuse (with rating below symbol) Low Impedence Warning or Caution To ensure safe operation and service of this meter, follow all warnings and instructions detailed in this manual. Risk of Electrical Shock Improper use of this meter can lead to risk of electrical shock. Follow all warnings and instructions detailed in this manual. SYMBOLS ON LCD H Data Hold Audible Continuity Diode Auto Ranging AC (Alternating Current) DC (Direct Current) Low Battery Auto Power Off MAX Maximum Value MIN Minimum Value °F Degrees Fahrenheit °C Degrees Celsius M Mega (value x 106) k kilo (value x 103) m mili (value x 10-3) μ micro (value x 10-6) n nano (value x 10 ) -9 V Volts A Amps F Farads Ohms Hz Hertz (Frequency) % Duty-Cycle REL Relative Mode Bar Graph 6 FEATURE DETAILS 1 7 9 8 10 11 2 3 5 6 4 NOTE: There are no user-serviceable parts inside meter. 1. 4000 count LCD display 7. "RANGE" button 2. Function selector switch 8. "REL" (Relative) button 3. "10A" jack 9. "MAX/MIN" button 4. "COM" jack 10. "HOLD" button 5. "VΩ" jack 11. "SEL" (Select) button 6. mA / µA jack 7 ENGLISH FUNCTION BUTTONS ON/OFF To Power ON the meter rotate the Function Selector switch 2 from the OFF setting to any measurement setting. To Power OFF the meter rotate the Function Selector switch 2 to the OFF setting. By default the meter will automatically Power OFF after 30 minutes of inactivity. Reactivate meter by pressing any button. To deactivate the automatic Power OFF feature, power the meter ON with the SEL button 11 depressed. When automatic Power OFF is deactivated, the symbol will not be visible in the display. When the Function Selector switch is rotated to a measurement setting, "LEAD" flashes on the display as a reminder to check that test leads are inserted into the appropriate jacks. "SEL" (SELECT) BUTTON (FOR SECONDARY FUNCTIONS) The "SEL" button 11 activates the secondary functions for each setting accessible by the Function Selector switch 2 . For Current, Voltage and Low Z, it toggles between AC and DC. For the other functions, it switches between °F and °C, between Hz and % Duty-cycle, and between Continuity, Resistance, and Diode-test. The default function for each application is printed on the meter in white; the secondary functions are printed on the meter in orange. "HOLD" (DATA HOLD / BACKLIGHT) BUTTON Press HOLD 10 to hold the measurement on the display. Press again to release the display to return to live measuring. Press and hold the "HOLD" button 10 for more than one second to turn on or off the backlight. The backlight will automatically Power…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CBM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CBM MM720 is an automatic-ranging digital multimeter for electrical troubleshooting and maintenance. It delivers True RMS measurement accuracy with Low Impedance mode and audible continuity testing. Ideal for field technicians and service professionals requiring reliable voltage, current, and resistance measurements.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a CBM MM720 multimeter in the Philippines?

Order the CBM MM720 from 3G Electric Philippines. We deliver to Manila, Quezon City, and across the Philippines with full logistics and Bureau of Customs documentation support. Lead time available on request.

What is the lead time for the CBM MM720 multimeter?

Lead time for the CBM MM720 depends on current availability. Contact 3G Electric Philippines for a quote and delivery schedule. We handle all customs clearance and PHP invoicing for imports to the Philippines.

Does the CBM MM720 have True RMS measurement capability?

Yes. The CBM MM720 features True RMS measurement with automatic ranging, Low Impedance mode, audible continuity testing, and Min/Max/Relative functions. It meets UL 61010-1, 61010-2-030, 61010-2-033 and CSA C22.2 standards. Calibration interval: 1 year.

Used in

Common applications for CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Products

3G Electric supplies CBM measurement & detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from CBM

View all CBM parts
CBM
CBM
Infrared thermometer with type K input
CBM
CBM
Multimeter case
CBM
CBM
Continuity tester
CBM
CBM
Phase indicator
CBM
CBM
Pump for expansion tank
CBM
CBM
Multifunction inflator battery 2500 mAH
CBM
CBM
Automatic multimeter MM420
CBM
CBM
AC/DC clamp meter