We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
DungsGas Regulation

Dungs Pink spring 100/150 MB for FRS 510

Dungs pink setpoint spring for FRS 510 gas regulation systems, rated 100/150 mbar. Designed for precise pressure control in gas safety equipment applications requiring reliable spring-based regulation.

SKU 3G-CBM-04012

Also listed as: GAZ 06006 · GAZ-06006

Brand
Dungs
Item
Pink spring 100/150 MB for FRS 510
Category
Gas Regulation
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dungs
type
setpoint spring
color
pink
application
FRS 510
pressure range
100/150 mbar

Datasheet Content

CD Betriebs- und Montage­ Operation and assembly Notice d 1 emploi et de lstruzioni di esercizio di anleitung instructions montage montaggio Sollwert-Federwechsel Change of setpoint spring Changement du ressort Molla di taratura valore de réglage" nominale Gas-Druckregelgerit Gas pressure regulator Régulateur de pression de gaz Regolatore di pressione del Typ FR... Type FR... Type FR... . gasTipo FR... 1 Schutzkappe 1 Oust cap 1 Capot de protection 1 Cappucio di protezione 2 Verstellspindel 2 Adjusting spindle 2 Vis sans fin de réglage 2 Vite di regolazione 3 Verstelleinrichtung 3 Setting mechanism 3 Disopositif de réglage 3 Dispositivo di regolazione komplett corniste complet completo 4 Distanzstück 4 Spacer 4 Entretoise 4 Distanziatore 5 Sollwertfeder 5 Setpoint spring 5 Ressort de réglage 5 molla di taratura valore nominale -ir->,..J,------------1 3 -.1-1-+�����(!) ...,..,..-=>� ?=�+-����------'� -------© Federwechsel Change of spring Changement du ressort Sostituzione della molla 1. Schutzkappe entfernen. 1. Remove dust cap. 1. Enlever le capot de protection. 1. Togliere il cappuccio di protezione. 2. Sollwertfeder enstpannen durch 2. Relieve setpoint spring by turning 2. Détendre le ressort de réglage èn 2. Distendere la molla di taratura valore Linksdrehen der Verstellspindel adjusting spindle anticlockwise tournant vers la gauche la vis sans nominale girando in senso antirario la gegen den Anschlag. towards stop. fin jusqu'en butée. vite di regolazione fino ail' arresto. Verletzungsgefahr Risk of injury Risque de blessure Pericolo di ferimenti! Bei Arbeiten am FR... Never keep your héad Lors de travaux effectués Eseguendo lavori all'FR... niemals Kopf über Re­ above the contrai de­ sur le FR... , ne jamais res­ non. mettere mai la testa gelgerat halten. vice when working on ter avec la tête au dessus sopra l'apparecchio di Verletzungsgefahr beim Wechseln the FR... de l'appareil de réglage. regolazione. der Feder, Sollwertfeder kann nicht Risk of injury when changing the Risque de blessure lors du rem­ Eseguendo la sostituzione della vollstandig entspannt werden. ·spring; set value spring cannot be placement du ressort ; le ressort molla si corre il rischio di ferimenti, released completely. de consigne ne peut pas être poiché la molla valore nominale non entièrement détendu. viene completamente scaricata. 3. Komplette Verstelleinrichtung ab­ 3. Screw off complete setting 3. Démonter l'ensemble du dispositif 3. Svitare l'intero dispositivo di rego­ schrauben und die Sollwertfeder mechanism and take out spring. de réglage et retirer le ressort. lazione e togliere la molla. ::f "' herausnehmen. N 4. Nur bei Sollwertfeder Nr-.8 und 9 4. Only for setpoint spring no.8 and 9 4. Seulement pour le montage du 4. Solo per il montaggio della molla di FR... ON 40 - DN 150: FR... DN 40 - 150: ressort de réglage No.8 et 9 taratura valore nominale nr. 8 e 9 � Distanzstück zur unteren An- Push spacer on to spindle in FR... DN 40 - DN 150: FR... ON 40 - DN 150: g schlagbegrenzung nach Zeich- accordance with drawing until it Placer et emboîter l'entreoise de Piazzare il distanziatore per la limita- § nung an der Verstellspindel engages against the bottom limit limitation de la butée inférieure zionedi arresto inferiore sui mandrino � aufsetzen und einrasten. stop and locks. selon dessin. di regolazione e bloccarlo. • 5. Sollwertfedereinsetzen, komplette 5. lnsert spring, mount complete 5. Mettre en place le ressort et re­ 5. Mettra la molla, montare il dipo­ 13 Verstelleinrichtung montieren und setting mechanism and adjust to monter l'ensemble du dispositif sitivo di regolazione completo · e 2 O gewünschten Ausgangsdruck required initial pressure. Screw on de réglage. Ajuster le pression de regolare la . pressione di uscita ) justieren. Schutzkappeaufschrau- dust cap. Gum spring indentifica­ sortie. Visser le capot de protection. desiderata. Riawitare il cappuccio '; ben. Klebeschild der Federkenn- tion label on to type plate. Poser l'autocollant correspondant di protezione. lncollare la targhetta � j zeichnung auf das Typenschild à la désignation du ressort sur la di identificazione della molla sulla aufkleben. plaque signalétique. targhetta. _.; Achtung: Distanzstück darfnur Attention: Use spacer onlyfor Utiliser l'entreoise seulement Attenzione: Utilizzare il di­ beim Einbau der Sollwertfeder installing spring No.8 and '9 pour la. montage du ressort stanziatore solo per il monta­ j Nr.8 und 9 in FR... DN 40 - DN into FR... DN 40 - DN 150! No.a et 9, FR... DN 40 - DN gio della molla nr. 8 e 9 nell' it 150 verwendet werden! 150! FR... DN 40 - DN 150! 1 ... 4

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dungs pink setpoint spring for FRS 510 gas regulation systems, rated 100/150 mbar. Designed for precise pressure control in gas safety equipment applications requiring reliable spring-based regulation.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Dungs pink spring 100/150 mbar for FRS 510 in the Philippines?

3G Electric Philippines supplies Dungs FRS 510 regulation components including this pink setpoint spring. We deliver to Manila, Quezon City, and across CALABARZON. We handle Bureau of Customs documentation and provide PHP invoicing for all orders.

What is the lead time for a Dungs GAZ06006 pink spring?

Lead time for the Dungs pink spring 100/150 mbar depends on current stock and origin logistics. Contact 3G Electric for availability and delivery schedule to your Philippines location. We manage all customs clearance.

What pressure range does the Dungs pink spring 100/150 mbar support?

This Dungs setpoint spring is rated for 100/150 mbar pressure control in FRS 510 gas regulation systems. It provides precise pressure regulation for gas safety applications requiring reliable spring-based control.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas regulation. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pink spring 100/150 MB for FRS 515
Dungs
Pink spring 100/150 MB for FRS 515
Yellow spring 30-70 MB for FRS 507
Dungs
Yellow spring 30-70 MB for FRS 507
Black spring 60/110 MB for FRS 507
Dungs
Black spring 60/110 MB for FRS 507
Regulator FRS 510 R 1"
Dungs
Regulator FRS 510 R 1"
FRS 505 R 1/2" regulator
Dungs
FRS 505 R 1/2" regulator
Regulator FRS 507 R 3/4"
Dungs
Regulator FRS 507 R 3/4"

More from Dungs

View all Dungs parts
Valve MBDLE 410 B01.S20
Dungs
Valve MBDLE 410 B01.S20
Regulator FRS 520 R 2"
Dungs
Regulator FRS 520 R 2"
MVDLE 515/5 valve 1"1/2
Dungs
MVDLE 515/5 valve 1"1/2
Pressure switch GW 50 A6 5-50 Mbar
Dungs
Pressure switch GW 50 A6 5-50 Mbar
Dungs
Dungs
Pink spring 100/150 MB for FRS 507
Dungs
Dungs
Valve MBDLE 420 B01.S50
Dungs
Dungs
Valve MBDLE 415 B01.S50
Dungs
Dungs
MBDLE 405 B01.S22 valve