Fantini Cosmi Hygrostat DIN rail 1 outlet L23EM1A 230V

Fantini Cosmi hygrostat for DIN rail installation provides humidity control across 0-100 RH% with ±0.7 RH% accuracy. Single outlet 230V AC unit offers IP40 protection, suitable for HVAC and building automation…

SKU 3G-CBM-03659

Also listed as: FAN 24050 · FAN-24050

Brand
Fantini Cosmi
Item
Hygrostat DIN rail 1 outlet L23EM1A 230V
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fantini Cosmi
type
hygrostat
outputs
1
accuracy
±0.7 RH%
mounting
DIN_rail
resolution
1
power supply
230V AC
measuring range
0-100 RH%
protection degree
IP40

Datasheet Content

L23EM1A Humidistat, DIN rail mounting For humidification or dehumidification systems with 1 outlet. 61 71 Dimensions (mm) 98 Sensor Num Power supply Measuring Resolution Measuring Degree of outputs range accuracy protection RH% RH% (0-100 RH%) L23EM1A probe (LS160A) 1 230 Vac 0 - 100 1 <± 0.7 IP40 back panel ELECTRICAL CHARACTERISTICS Output on single-pole relay in deviation. Contact rating 16(4)A 240 Vac. Power consumption 3W. REGULATIONS AND APPROVALS Compliant with EN60730-1, EN60730-2-9, EN55022 (CLASS B), EN50082-1. INSTALLATION DIN rail mounting. 16 OPERATION Type of control: can operate in ON/OFF or PID mode. ON/OFF control: in ON/OFF mode the output is ON or OFF depending on the input humidity, setpoint (1SP) and hysteresis value (1HY). The hysteresis indicates the amplitude of the deviation of the setpoint humidity to reactivate the output. PID control: in PID mode the output is ON for a fraction of cycle time 1CT. The cycle time characterises the dynamics of the system to be controlled and influences the accuracy of the control. Proportional control. Integrative proportional control. FEATURES Configurable parameters: „ dehumidification or humidification function by assigning positive or negative sign to the differential respectively. „ minimum or maximum setpoint limits. „ ON or OFF status of the output in the event of a defective probe. Operating temperature -10 to 50°C. Degree of protection IP40. ACCESSORIES LS160A RH% probe, scale range from 0 to 100 %RH L 17

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fantini Cosmi hygrostat for DIN rail installation provides humidity control across 0-100 RH% with ±0.7 RH% accuracy. Single outlet 230V AC unit offers IP40 protection, suitable for HVAC and building automation systems requiring precise moisture regulation.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Fantini Cosmi L23EM1A hygrostat in the Philippines?

3G Electric Philippines is an authorized distributor. We supply the L23EM1A hygrostat with delivery to Manila, Quezon City, and CALABARZON regions. We handle Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for availability and lead time on request.

What is the lead time and shipping cost for the L23EM1A to the Philippines?

Lead time varies by stock status. 3G Electric coordinates all logistics and customs clearance to your facility in the Philippines. For a specific delivery quote and lead-time estimate, please request a quotation with your purchase volume and location.

What humidity range and accuracy does the Fantini Cosmi L23EM1A provide?

The L23EM1A measures 0–100 RH% (relative humidity) with ±0.7 RH% accuracy. It is IP40 rated, 230V AC powered, and mounts on DIN rail for HVAC and building automation systems requiring precise moisture control.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP