We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fantini Cosmi ON/OFF thermostat 2 outlets L02DM2 115/230V - Switches & Thermostats
Fantini CosmiSwitches & Thermostats

Fantini Cosmi ON/OFF thermostat 2 outlets L02DM2 115/230V

Fantini Cosmi ON/OFF thermostat with 2 outlets for HVAC and industrial temperature control. Features 1 NTC 10K probe with ±0.3°C accuracy across -40 to 105°C range and 0.1°C resolution. 12Vac/dc powered unit rated…

SKU 3G-CBM-03648

Also listed as: FAN 24020 · FAN-24020

Brand
Fantini Cosmi
Item
ON/OFF thermostat 2 outlets L02DM2 115/230V
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fantini Cosmi
type
ON/OFF thermostat with 2 outputs
sensor
1 NTC 10K probe LS130
resolution
0.1°C (-19.9-99.9), 1°C
power supply
12Vac/dc
probe accuracy
±0.3°C (-40-100), ±1°C
measuring range
-40 to 105°C
degree of protection
IP55 (panel)

Datasheet Content

■ Pendant la phase d’autotest, appuyer sur les touches + , et les garder appuyées jusqu’à ce que l’appareil affiche 0AD. MODE D’EMPLOI ■ Avec les touches et sélectionner 0AD ou SAD: 0AD permet la calibration du 0 en introduisant une correction constante sur 2DF -19.9...19.9° Différentiel de température par rapport à 1SP. Le point de consigne de la sortie auxiliaire correspond à 1SP+2DF toute l’échelle de mesure. SAD permet la calibration de la partie haute de l’échelle de mesure avec une correction proportionnelle Nous vous remercions d’avoir choisi un produit Fantini Cosmi. Pour que votre instrument soit le plus sûr et le plus performant ON entre le point de calibration et le 0. ON possible, il est indispensable d’en lire attentivement le mode d’emploi. ■ Appuyer sur pour afficher la valeur et agir avec + ou pour faire coïncider la valeur lue avec celle mesurée par 2SM=REL DESCRIPTION INDICATIONS l’instrument de référence; OFF OFF ■ Pour quitter la calibration, appuyer sur la touche . OUT1 Sortie canal 1 2DF>0 1SP+2DF+2HY T[°] 1SP+2DF-2HY 2DF<0 T[°] PARAMETRES DE CONFIGURATION 1SP 1SP+2DF 1SP+2DF 1SP OUT2 Sortie canal 2 Contrôle ON/OFF en réfrigération. Point de Contrôle ON/OFF en chauffage. Point de ■ Pour accéder au menu de configuration des paramètres, presser pendant 5 secondes les touches + . OAU=THR consigne 2 relatif au point de consigne 1 consigne 2 relatif au point de consigne 1 L1 Modification point de consigne 1 ■ Avec les touches ou sélectionner le paramètre à modifier. (OAU=THR, 2CH=REF) (OAU=THR, 2CH=HEA) ■ Presser la touche pour afficher la valeur. L2 Modification point de consigne 2 2CH REF; HEA Modalité de régulation réfrigération (REF) ou chauffage (HEA) pour la sortie auxiliaire. ■ Tout en maintenant la touche pressée, agir avec les touches ou pour fixer la valeur désirée. Alarme ■ La nouvelle valeur est mémorisée et le paramètre suivant est affiché lorsque l’on cesse de presser la touche 2HY 0...19.9° Différentiel OFF/ON en mode 2. Avec 2HY=0 la sortie reste éteinte ■ Pour sortir du réglage, presser la touche ou attendre 30 secondes. Fig.1 — Panneau avant 2T0 0...30min Temps minimum d’arrêt. Touche augmentation / Modification point de consigne 2 Après un arrêt, la sortie 2 reste désactivée pendant 2T0 minutes indépendamment de la valeur Touche Info / Enter. PAR PLAGE DE DESCRIPTION de la température. Modification point de consigne 1 / diminution. Touche sortie / Stand-by. MESURE INSTALLATION 2T1 0...30min Temps minimum d’activation SCL 1°C; Échelle de lecture. (voir table des caractéristiques entrée) Après la mise en marche, la sortie 2 reste activée pendant 2T1 minutes indépendamment de la 2°C; Attention: si la valeur de SCL est modifiée, les paramètres concernant les températures absolues ■ Introduire l’instrument dans un trou de 71x29 mm. valeur de la température. °F et relatives (SPL, SPH, 1SP, 1HY etc..) doivent absolument être reconfigurés. ■ Effectuer les raccordements électriques en suivant les indications du paragraphe “schémas de raccordement”. Pour réduire les effets des perturbations électromagnétiques, éloigner des conducteurs de puissance les câbles des sondes et de signal.…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fantini Cosmi ON/OFF thermostat with 2 outlets for HVAC and industrial temperature control. Features 1 NTC 10K probe with ±0.3°C accuracy across -40 to 105°C range and 0.1°C resolution. 12Vac/dc powered unit rated IP55 for panel mounting.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Fantini Cosmi L02DM2 thermostat in the Philippines?

3G Electric Philippines supplies the Fantini Cosmi L02DM2 thermostat with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for lead times and quotations.

What is the lead time for the L02DM2 thermostat from 3G Electric?

Lead time varies based on current availability. The L02DM2 is available to order through 3G Electric Philippines. Request a formal quotation for specific delivery schedules to your location in the Philippines, including CALABARZON industrial zones.

What temperature range and accuracy does the Fantini Cosmi L02DM2 provide?

The L02DM2 measures -40 to 105°C with ±0.3°C accuracy across -40 to 100°C using a 1 NTC 10K probe LS130. Resolution is 0.1°C in the -19.9 to 99.9°C range, making it suitable for precise HVAC and industrial temperature control applications.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
ON/OFF thermostat 2 outlets L02AM2 115/230V
Fantini Cosmi
ON/OFF thermostat 2 outlets L02AM2 115/230V
ON/OFF thermostat 2 outputs L02CM2 115/230V
Fantini Cosmi
ON/OFF thermostat 2 outputs L02CM2 115/230V
ON/OFF thermostat 2 outlets L02CI2B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 2 outlets L02CI2B 12VAC/DC
ON/OFF thermostat 1 output L02DM1 115/230V
Fantini Cosmi
ON/OFF thermostat 1 output L02DM1 115/230V
ON/OFF thermostat 1 output L02CM1 115/230V
Fantini Cosmi
ON/OFF thermostat 1 output L02CM1 115/230V
ON/OFF thermostat 1 output L02BM1A 230V
Fantini Cosmi
ON/OFF thermostat 1 output L02BM1A 230V

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP