We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fantini Cosmi ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC - Switches & Thermostats
Fantini CosmiSwitches & Thermostats

Fantini Cosmi ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC

Fantini Cosmi ON/OFF thermostat with 1 outlet for HVAC and industrial temperature control. Features NTC 10K probe with ±0.3°C accuracy across -40 to 100°C range and 0.1°C resolution. Flush-mounted IP55 design powered…

SKU 3G-CBM-03641

Also listed as: FAN 24006 · FAN-24006

Brand
Fantini Cosmi
Item
ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fantini Cosmi
sensor
1 NTC 10K probe LS130
outputs
1
mounting
flush
protection
IP55
resolution
0.1°C (-19.9 to 99.9), 1°C
power supply
12VAC/DC
probe accuracy
±0.3°C (-40 to 100), ±1°C
measuring range
-40 to 105°C

Datasheet Content

■ Pendant la phase d’autotest, appuyer sur les touches + , et les garder appuyées jusqu’à ce que l’appareil affiche 0AD. MODE D’EMPLOI ■ Avec les touches et sélectionner 0AD ou SAD: 0AD permet la calibration du 0 en introduisant une correction constante sur 2DF -19.9...19.9° Différentiel de température par rapport à 1SP. Le point de consigne de la sortie auxiliaire correspond à 1SP+2DF toute l’échelle de mesure. SAD permet la calibration de la partie haute de l’échelle de mesure avec une correction proportionnelle Nous vous remercions d’avoir choisi un produit Fantini Cosmi. Pour que votre instrument soit le plus sûr et le plus performant ON entre le point de calibration et le 0. ON possible, il est indispensable d’en lire attentivement le mode d’emploi. ■ Appuyer sur pour afficher la valeur et agir avec + ou pour faire coïncider la valeur lue avec celle mesurée par 2SM=REL DESCRIPTION INDICATIONS l’instrument de référence; OFF OFF ■ Pour quitter la calibration, appuyer sur la touche . OUT1 Sortie canal 1 2DF>0 1SP+2DF+2HY T[°] 1SP+2DF-2HY 2DF<0 T[°] PARAMETRES DE CONFIGURATION 1SP 1SP+2DF 1SP+2DF 1SP OUT2 Sortie canal 2 Contrôle ON/OFF en réfrigération. Point de Contrôle ON/OFF en chauffage. Point de ■ Pour accéder au menu de configuration des paramètres, presser pendant 5 secondes les touches + . OAU=THR consigne 2 relatif au point de consigne 1 consigne 2 relatif au point de consigne 1 L1 Modification point de consigne 1 ■ Avec les touches ou sélectionner le paramètre à modifier. (OAU=THR, 2CH=REF) (OAU=THR, 2CH=HEA) ■ Presser la touche pour afficher la valeur. L2 Modification point de consigne 2 2CH REF; HEA Modalité de régulation réfrigération (REF) ou chauffage (HEA) pour la sortie auxiliaire. ■ Tout en maintenant la touche pressée, agir avec les touches ou pour fixer la valeur désirée. Alarme ■ La nouvelle valeur est mémorisée et le paramètre suivant est affiché lorsque l’on cesse de presser la touche 2HY 0...19.9° Différentiel OFF/ON en mode 2. Avec 2HY=0 la sortie reste éteinte ■ Pour sortir du réglage, presser la touche ou attendre 30 secondes. Fig.1 — Panneau avant 2T0 0...30min Temps minimum d’arrêt. Touche augmentation / Modification point de consigne 2 Après un arrêt, la sortie 2 reste désactivée pendant 2T0 minutes indépendamment de la valeur Touche Info / Enter. PAR PLAGE DE DESCRIPTION de la température. Modification point de consigne 1 / diminution. Touche sortie / Stand-by. MESURE INSTALLATION 2T1 0...30min Temps minimum d’activation SCL 1°C; Échelle de lecture. (voir table des caractéristiques entrée) Après la mise en marche, la sortie 2 reste activée pendant 2T1 minutes indépendamment de la 2°C; Attention: si la valeur de SCL est modifiée, les paramètres concernant les températures absolues ■ Introduire l’instrument dans un trou de 71x29 mm. valeur de la température. °F et relatives (SPL, SPH, 1SP, 1HY etc..) doivent absolument être reconfigurés. ■ Effectuer les raccordements électriques en suivant les indications du paragraphe “schémas de raccordement”. Pour réduire les effets des perturbations électromagnétiques, éloigner des conducteurs de puissance les câbles des sondes et de signal.…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fantini Cosmi ON/OFF thermostat with 1 outlet for HVAC and industrial temperature control. Features NTC 10K probe with ±0.3°C accuracy across -40 to 100°C range and 0.1°C resolution. Flush-mounted IP55 design powered by 12VAC/DC for reliable switching applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Fantini Cosmi L02CI1B thermostat in the Philippines?

Source the L02CI1B from 3G Electric Philippines. We deliver to Manila, Quezon City, and across the Philippines. 3G Electric handles customs clearance, Bureau of Customs documentation, and logistics. Lead time on request.

What is the temperature accuracy and measuring range of the L02CI1B?

The L02CI1B offers ±0.3°C accuracy across -40 to 100°C and ±1°C at extremes. Measuring range is -40 to 105°C with 0.1°C resolution. NTC 10K probe (LS130) sensor ensures reliable industrial HVAC control.

What mounting and power supply does this thermostat require?

The L02CI1B is flush-mounted, IP55 rated for harsh environments. Powered by 12VAC/DC with 1 ON/OFF outlet for direct switching. Compact design suits panel mounting in HVAC and industrial temperature control systems.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
IO-Link compact vacuum pressure switch with 1/8 in port size. Operates on 12 to 24V DC and provides 1 Output/2 Output NPN/PNP open collector configurations. Connects via a 4-pin snap-in plug. Used in industrial automation for monitoring vacuum levels in pneumatic systems, such as process control and leak detection
SMC
IO-Link compact vacuum pressure switch with 1/8 in port size. Operates on 12 to 24V DC and provides 1 Output/2 Output NPN/PNP open collector configurations. Connects via a 4-pin snap-in plug. Used in industrial automation for monitoring vacuum levels in pneumatic systems, such as process control and leak detection
The SMC ZSE20-P-N01-LA1 is a high precision vacuum pressure switch with a 1/8 in port size. It features a selectable 1 NPN/PNP output and operates on 12 to 24V DC power, with a 4-Pin Snap-In Plug connection. Suitable for precise vacuum pressure monitoring in industrial automation, packaging, and material handling systems
SMC
The SMC ZSE20-P-N01-LA1 is a high precision vacuum pressure switch with a 1/8 in port size. It features a selectable 1 NPN/PNP output and operates on 12 to 24V DC power, with a 4-Pin Snap-In Plug connection. Suitable for precise vacuum pressure monitoring in industrial automation, packaging, and material handling systems
High precision vacuum pressure switch from the ZSE20(F) series. Features a 1/8 in port, single NPN/PNP output, 12 to 24V DC supply, and hardwired connection. Operating temperature range -5°C to 50°C. Suitable for vacuum pressure monitoring in pneumatic control circuits and industrial automation
SMC
High precision vacuum pressure switch from the ZSE20(F) series. Features a 1/8 in port, single NPN/PNP output, 12 to 24V DC supply, and hardwired connection. Operating temperature range -5°C to 50°C. Suitable for vacuum pressure monitoring in pneumatic control circuits and industrial automation
Compact vacuum pressure switch with 1 PNP open collector output, operating on 12 to 24V DC. Sensing range from -101 kPa to 0 kPa, ambient temperature 0°C to 60°C. Equipped with a 4-pin snap-in plug. Used for vacuum level monitoring in pneumatic circuits and automation systems
SMC
Compact vacuum pressure switch with 1 PNP open collector output, operating on 12 to 24V DC. Sensing range from -101 kPa to 0 kPa, ambient temperature 0°C to 60°C. Equipped with a 4-pin snap-in plug. Used for vacuum level monitoring in pneumatic circuits and automation systems

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP