We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Elektrogas Sealing control unit LDM2 230V - Gas Valves
ElektrogasGas Valves

Elektrogas Sealing control unit LDM2 230V

Elektrogas LDM2 is a sealing control unit for gas valve applications, operating at 230V with EN 161 class A solenoid valves and IP65 enclosure rating. Maximum output signal reaches 5A resistive, supporting tightness…

SKU 3G-CBM-03204

Also listed as: ELK 60004 · ELK-60004

Brand
Elektrogas
Item
Sealing control unit LDM2 230V
Category
Gas Valves
UNSPSC
40141609 — Control valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Elektrogas
fuse
5A slow-acting
type
LDM2 Tightness Control Device
voltage
230V
cable gland
PG9, PG16, PG11
output signal
5A max resistive
pressure switch
EN 1854 compliant
solenoid valves
EN 161 class A
enclosure rating
IP65

Datasheet Content

LD, LDM Tightness Control Device delta-elektrogas.com EE172 -10/17 ELEKTROGAS – Technical Sheet EE172- 10/17 LD, LDM Tightness Control Device Contents Description ………………………………………..….. 2 Features ……..……………………………..……..….. 2 Functioning ………………….............……….………. 3 Applications ….……………………………..……….... 6 Sizing and adjustments ……………………………... 8 Technical specifications ………………………...…. 13 Installation …………………………………………… 15 Ordering information ……..……………...…………. 16 Accessories …………………………………………. 16 Standard and approvals ……….…………......…..... 17 Description The LD/LDM tightness control device is designed to verify the absence of inadmissible leaks in gas trains composed by automatic shutoff valves. The check can be performed before the ignition of the gas burner or after its stop. This device is used in industrial firing processes and in forced draught burners, when power is higher than 1200 kW, according to EN 746-2 and EN 676. Features Microcontroller technology Easy-to-see status of the device through high visibility LEDs Easy accessible reset button Adjustable test time to meet the plant needs Adjustable test instant Available Ex-proof version with metal enclosure for installation in Zone 2 and 22 (ATEX) Available with integrated pressure switches and/or integrated auxiliary valves Designed and manufactured according to EN 1643 WARNING This control must be installed in compliance with the rules in force. 2 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 Functioning Fig. 1 LD1 Basic version is composed by electronic control only (Fig.1). This device, coupled to an external pressure switch, checks the pressure in the test volume VT (yellow color in Fig.2), detecting potential leaks from shutoff valves. The test is performed in two steps: 1 The upstream valve is tested discharging the test volume and monitoring the pressure increasing (pressure switch on NO contact). 2 The downstream valve is tested filling the test volume and monitoring the pressure decreasing (pressure switch on NC contact). Pressure set up of the switch is usually half of inlet pressure (PT=P1/2). The operational steps of charging and discharging test volume are done by the valves V1 e V2. Fig. 2 3 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 LD3 Version with two integrated auxiliary valves for supply/discharge operations of the test volume VT (Fig.3). Fig. 3 LDM2 Version with metal enclosure and integrated pressure switch (Fig.4). Fig. 4 LDM4 Version with metal enclosure, integrated pressure switch and auxiliary valves (Fig.5). Fig. 5 4 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 Working cycle Power-up Led Fault V2 Led Fault V1 Led OK Led Test Diagnosis Led Alarm Led Power STEP DESCRIPTION tA 1 2 3 4 5 6 Power-up       NO OK Power supplied to terminal 3. Alarm Device runs a self-check (lasting tA) YES Alarm  A problem has occurred. Ready Signal F (fault) is sent to the control unit. The working cycle stops. Led2 is blinking according to the type of problem (see alarm table). Discharge Start Ready  No faults occurred. tO = 3 s Device is ready to receive the command S (start). Test V1 Discharge   Start signal S is received. tP Device opens V2 to discharge test volume. NO PT < P1/2 Leak from V1 (time tO = 3 s). Test V1   YES Device shuts V2 off and test for V1 begins (lasting tP). V1 OK Leak from V1   An unacceptable leak from V1 is detected. Filling Signal F (fault) is sent to the control unit. Cycle stops. to = 3 s V1 OK   The valve V1 is tight. Test V2 Filling   Device opens V1 to fill the test volume tP (time tO = 3 s). PT > P1/2 NO Leak from V2 Test V2   Device shuts V2 off and test for V2 begins (lasting tP). YES Leak from V2   V2 OK An unacceptable leak from V2 is detected. Signal F (fault) is sent to the control unit. Cycle stops. V2 OK   The valve V2 is tight. OK signal is sent to the control unit.  LED switched on Tab. 1  LED blinking 5 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 Applications In addition to the basic diagram shown in Fig. 2-5, other connections are possible. System with 2 safety valves and 2 pressure switches (Fig.6). In the case of a large test volume, in order to reduce the testing time, two pressure switches can be used and set with different pressure values PL and PH. When the tightness test is finished with positive result, the OK enable signal is sent to the burner control, which can now open the V1 and V2 valves. Fig.6 System with 2 safety valves and a auxiliary valve for the discharge (Fig.7). f the second valve V2 is a slow opening type, it is necessary to install an auxiliary valve with fast opening VD for the discharge into the combustion chamber (or in the atmosphere). The device checks the tightness of the valves V1 and V2 and the auxiliary valve VD. When the tightness test is finished with positive result, the OK enable signal is sent to the burner control, which can now open the valve V2. Fig.7 6 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 Multiple burner system with 2 safety valves installed in series and auxiliary valves for the filling and discharge (Fig.8). The device checks the tightness of the main valve V1, the auxiliary valves VF and VD and the safety valves of each burner. When the tightness test is finished with a positive result, the OK enable signal opens the main valve V1 and it is sent to the burner control, to enable the opening of the valves of each burner. Fig.8 Multiple burner system with 3 safety valves installed in series (Fig.9) If the main valves V1 and V2 are slow opening is necessary to install the VF and VD auxiliary valves for filling and discharging of the test volume VT. The device checks the tightness of the main valves V1 and V2 and the auxiliary valves VF and VD. The valve V2 can only be tested if the downstream pressure is approximately equal to the atmospheric pressure and the volume of this chamber is at least equal to 5xVT. To this purpose the VK valve is opened by the Start-up signal to relieve the pressure at the value which is adjusted with the pressure switch P2 (it must be calibrated so as to detect minimum increases of pressure). When the tightness test is finished with positive result, the OK signal disables the VK valve (via the K normally closed contact), opens the valves V1 and V2 and, at the same time, enables the control units of each burner located downstream. Fig.9 7 / 17 ELEKTROGAS – Technical Sheet EE172- 10/17 Sizing and adjustments Leakage rate According the EN 1673…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Elektrogas Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Elektrogas LDM2 is a sealing control unit for gas valve applications, operating at 230V with EN 161 class A solenoid valves and IP65 enclosure rating. Maximum output signal reaches 5A resistive, supporting tightness control in industrial gas systems with EN 1854-compliant pressure switching.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Elektrogas LDM2 sealing control unit in the Philippines?

3G Electric Philippines supplies the Elektrogas LDM2 230V sealing control unit with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation and logistics. Contact us for pricing and lead time on request.

What is the lead time for the Elektrogas LDM2 230V?

The Elektrogas LDM2 is available to order. Lead time depends on current stock and supply chain conditions. 3G Electric handles all customs clearance and delivery to Philippines. Request a quotation for specific timeline details.

What solenoid valves are compatible with the LDM2 sealing control unit?

The Elektrogas LDM2 is designed for EN 161 class A solenoid valves with a maximum resistive output signal of 5A. The unit features IP65 enclosure rating and supports EN 1854-compliant pressure switching for industrial gas tightness control applications.

Used in

Common applications for Elektrogas
Industrial steam and hot-water boiler gas trains — VMR slow-opening solenoid valves on modulating burners
Commercial kitchen and bakery gas-fired ovens — VML magnetic valves for appliance-level safety shut-off
Process-industry gas supply skids — VMH high-pressure variants rated to 6 bar for elevated-pressure networks
Burner OEM gas-train assemblies — multibloc combined-function units reducing commissioning and leak paths
Retrofit drop-in replacements for existing Elektrogas VMR valves on installed burner racks

Elektrogas Products

3G Electric supplies Elektrogas gas valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Leak control unit LDM2 230V Atex
Elektrogas
Leak control unit LDM2 230V Atex
Elektrogas
Elektrogas
Tightness controller LD1 230V
Tightness controller LD3 230V
Elektrogas
Tightness controller LD3 230V
Tightness controller LDM4 230V (pressure switch 25/100 mbar)
Elektrogas
Tightness controller LDM4 230V (pressure switch 25/100 mbar)
Elektrogas
Elektrogas
Tightness controller LDM4 230V Atex
1930.4110 230V EVRMNAOT 3/8"-2" 600mbar-6bar coil
Elektrogas
1930.4110 230V EVRMNAOT 3/8"-2" 600mbar-6bar coil

More from Elektrogas

View all Elektrogas parts
Solenoid valve VMR 2-60 tapped D3/4" 6 Bar
Elektrogas
Solenoid valve VMR 2-60 tapped D3/4" 6 Bar
Solenoid valve VMR 4-60 tapped D1"1/2 6 Bar
Elektrogas
Solenoid valve VMR 4-60 tapped D1"1/2 6 Bar
Elektrogas
Elektrogas
VMRNA 3-60 vent valve threaded D.1" 6 bar
Multiblock VMM205AF01 D20 500Mb quick valve with bypass D15 left side
Elektrogas
Multiblock VMM205AF01 D20 500Mb quick valve with bypass D15 left side
Elektrogas
Elektrogas
Solenoid EVRM NA 2 threaded D3/4" 600 Mbar
Solenoid valve VMR 8 flanged DN80 360 Mbar
Elektrogas
Solenoid valve VMR 8 flanged DN80 360 Mbar
Solenoid valve VML 1-60 threaded D1/2" 6 bar
Elektrogas
Solenoid valve VML 1-60 threaded D1/2" 6 bar
Elektrogas
Elektrogas
Solenoid valve VML2 threaded D3/4" 500 Mbar