The Ambiance RF programmable thermostat is a wireless climate control device rated for 6(2)A at 220V, featuring ±1°C temperature accuracy and an adjustable range of 7°C to 35°C. Powered by two AAA 1.5V lithium…

SKU 3G-CBM-00167

Also listed as: AMB 05004 · AMB-05004

Brand
Ambiance
Item
RF programmable thermostat
Category
Climate Controls
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Ambiance
load rating
6(2)A, 220V
power source
2x AAA 1.5V lithium battery
standby current
20µA
backlight colour
Blue
lighting current
≤3mA
temperature accuracy
±1°C at 20°C
display temperature range
0°C~40°C
adjustable temperature range
7°C~35°C

Datasheet Content

Mode d'emploi THERMOSTAT D'AMBIANCE RADIO FREQUENCE 3G-CBM-00167 Jour de la semaine Verrouillage de la température d’utilisation / Mode vacances Température de consigne Heure Témoin batterie Température ambiante faible Programme en cours Mode en cours PRÉSENTATION • Affichage de la température ambiante : 0°C~40°C (pas de 0,1°C) • Réglage de la température de consigne : 7°C - 35°C • Précision de la mesure de la température : ±1°C (à 20°C) • Alimentation : 2 piles au lithium AAA de 1,5 V • Classification de charge : 6(2) A, 220 V • Témoin de batterie faible : affiche le symbole " " lorsque la batterie est inférieure à 2,7 V • Courant de repos : 20µA, Courant d’éclairage ≤ 3mA • Rétroéclairage : bleu RÉGLAGE DE L'HEURE  Appuyer sur DAY jusqu’à ce que le symbole semaine clignote ; utiliser les touches + ou – pour régler entre 1 et 7.  Appuyer à nouveau sur DAY jusqu’à ce que le symbole heure clignote ; utiliser les touches + ou – pour régler entre 0 et 23.  Appuyer une nouvelle fois sur DAY jusqu’à ce que le symbole minutes clignote ; utiliser les touches + ou – pour régler entre 0 et 59.  Appuyer sur SET pour confirmer les réglages ou attendre 15 secondes pour une confirmation automatique et un retour au mode RUN. PROGRAMMATION Le thermostat dispose d’une programmation 5 jours / 2 jours ou 7 jours. La température de consigne se règle par tranche de 30 min sur une plage de 24h. Appuyer sur PROG en fonctionnement normal pour afficher les réglages : Programme par défaut : 22 : 00 – 05 : 59 Remarque : 06 : 00 – 07 : 59 08 : 00 – 17 : 59 Température économique 18 : 00 – 21 : 59 Température de confort Appuyer sur le bouton SET puis appuyer simultanément sur le bouton PROG ; Appuyer ensuite plusieurs fois sur PROG pour choisir votre programmation 5 jours / 2 jours ou 7 jours et SET pour valider. Une fois votre programmation choisie, appuyer sur le bouton SET puis appuyer simultanément sur le bouton PROG pour rentrer à nouveau dans le menu programmation : o Appuyer sur MODE pour passer de " ", température de confort, à " " température économique (en mode confort, des barres s'affichent sur le cadran) ; o Appuyer sur + ou – pour déterminer les différentes périodes de la journée ; o Lorsque le programme pour le premier jour est défini, appuyer sur PROG pour le réglage du jour suivant. 02 COPIE D'UN PROGRAMME Appuyer sur SET pour revenir au menu d’accueil. 1. Appuyer sur le bouton « COPY » pendant 3 secondes jusqu’à ce que le symbole COPY clignote (le jour 1 clignote également) 2. Appuyer sur « PROG » pour choisir un autre jour à copier si ce n’est pas celui que vous désirez. 3. Appuyer à nouveau sur COPY sur le jour choisi et COPY ne clignote plus. Appuyer ensuite sur « PROG » jusqu’au jour pour lequel vous souhaitez copier le programme et appuyer sur « COPY » pour confirmer ; les changements sont alors effectués immédiatement. 4. Répéter les étapes 2 et 3 ci-dessus pour copier différents programmes. 5. Appuyer sur SET pour valider ou attendre 15 secondes. MODE MANUEL Pour bloquer la température indéfiniment : • Appuyer une fois sur « HOLD » jusqu'à ce qu'un symbole HOLD apparaisse. Appuyer sur SET pour valider puis + ou – pour régler la température ; ces réglages seront effectifs jusqu’à ce que le bouton SET soit activé pour sortir de ce mode. Pour bloquer la température pendant plusieurs heures : • Appuyer sur + ou – pour ajuster la température de consigne puis appuyer sur DAY pour définir les heures de température de consigne. Appuyer sur + ou – pour choisir les heures pendant lesquelles la température de consigne sera appliquée, entre 1 et 9H. Appuyer sur SET pour valider ou attendre 15 secondes pour confirmation automatique. Appuyer sur SET pour quitter ce mode. Pour changer la température manuellement pendant une période de votre programme enregistré : • Appuyer sur + ou – pour régler la température de consigne (un symbole de main apparait) puis attendre 15 secondes pour confirmer automatiquement. La température de consigne sera appliquée jusqu’à l’application du programme suivant ou appuyer sur SET pour quitter ce mode. Au changement d’heure pleine à heure creuse de votre programme habituel, la température reviendra automatiquement à celle de votre programmation. MODE VACANCES Maintenir le bouton « HOLD » pendant 3 secondes jusqu’à ce que les symboles d:01 et le symbole valise s’affichent, appuyer sur + ou – pour choisir entre d:01 et d:99, appuyer sur SET pour valider ou attendre 15 secondes pour confirmation automatique. Appuyer ensuite sur + ou – pour ajuster à la température souhaitée et ne plus faire de manipulation. Ce réglage de température sera appliqué pour les jours paramétrés. Appuyer sur SET pour quitter ce mode. 03 RÉTROÉCLAIRAGE Appuyer sur LIGHT ou n’importe quelle autre touche ; le rétroéclairage sera alors actif pendant 15 secondes. RÉGLAGE DIVERS DIFFERENTIEL : Appuyer sur DAY et simultanément sur COPY pour accéder au réglage du différentiel. Appuyer sur + ou – pour choisir 01 ou 02 : S : 01 ±0.1°C ou S : 02 ± 0.2°C CALIBRAGE DE LA TEMPERATURE : Appuyer sur SET et simultanément sur MODE pour accéder au réglage de l’oscillation. Appuyer sur + ou - pour choisir la valeur souhaitée ; CAL : -3.0°C / +3.0°C. Ce calibrage permet d’ajuster la température ambiante. Exemple : s’il fait 22°C dans une pièce, pour CAL = +3.0°C, le thermostat affichera 25° C au lieu des 22°C réel. FONCTIONS DE VERROUILLAGE • Appuyer sur « LOCK » pendant 5 secondes jusqu’à ce que LOCK s’affiche sur l’écran accompagné du symbole en permanence. Tous les boutons sont alors verrouillés. • Appuyer à nouveau sur « LOCK » pendant 5 secondes jusqu’à ce que ULOC s’affiche et que le symbole disparaisse. Tous les boutons sont alors déverrouillés et le thermostat peut être utilisé normalement. MODE DE FONCTIONNEMENT et HORS GEL HEAT (Chauffage) / COOL (Refroidissement) / OFF (Hors gel). Passer d’un mode à l’autre en appuyant sur MODE pendant 5 secondes et utiliser les boutons + et – pour choisir le mode de fonctionnement entre le mode de chauffage, climatisation ou hors gel. Appuyer sur SET pour valider. En mode hors gel, la température est fixe à 7°C. RÉGLAGE DES TEMPÉRATURES DE CONSIGNE ET . Température de confort : - appuyer sur SET et simultanément sur « + » pour afficher le symbole et la température - appuyer ensuite sur + ou – pour modifier la température de confort et appuyer sur SET pour confirmer. Température économique : - appuyer sur SET et simultanément sur « - » pour afficher le symbole et la température ; - appuyer ensuite sur + ou – pour modifier la température de maintien et appuyer sur SET pour confirmer. APPAREILLAGE RF 1. Sous le mode de fonctionnement AUTO, appuyer sur le bouton M/A du récepteur pendant 10 secondes pour entrer dans ce mode. La lumière verte clignote. 2. Appuyer sur SET et DAY sur le transmetteur pendant 10 secondes ; la lumière verte du récepteur arrête de clignoter lorsque le signal est reçu. Le thermostat est alors appairé et le transmetteur peut désormais contrôler le récepteur. 04 RESET Retirer la paroi arrière puis appuyer sur le bouton RESET situé à l’arrière pour réinitialiser le thermostat (éteindre puis rallumer l’appareil ne changera pas les réglages). 2. Appuyer sur RESET sur la face avant pendant 3 secondes pour rétablir les réglages par défaut (sortie d’usine). SCHÉMA DE CABLAGE Enlever le capot de protection à l’arrière. Dévisser la vis située sur la face inférieure du boitier pour arriver au circuit comportant le relais. Thermostat d’ambiance à contact sec. 1 Contact normalement fermé (NC), 2 Contact inverseur (COM) 3 Contact normalement ouvert (NO) 05 Instruction Specification 1.Display Temperature Range:0°C~40°C (in 0.1°C increments) 2.Adjustable Temperature Range:7°C~35°C 3.Temperature measurement accuracy: ±1°C (at 20°C) 4.Power source: 2x AAA 1.5V LITHIUM BATTERY 5.Load Rating: 6(2)A, 220V 6.Low Battery Indicator: Display “ “ when battery is less than 2.7V 7.Standby current:20uA, Lighting current ≤ 3mA 8.Backlight colour: Blue Setting the Time 1.Press DAY once until the week symbol is flashing,use + or - to adjust from 1~7. 2.Press DAY once until the hour symbol is flashing,use + or - to adjust from 0~23. 3.Press DAY once until the minute symbol is flashing,use + or - to adjust from 0~59. 4.Press SET to confirm changes or wait for 15 secs to automatically confirm and return to the Run Mode. Programming 1. Hold SET then press PROG ; 2. Press “MODE” to “ ”(comfortable temperature) or “ ”(economic temperature); 3. Press + or - to select the setting time; 4. When DAY set up ,Press PROG turn to next day setting ; 5. Press PROG in normal operation to view the parameters; Program default: 22:00--05:59 ; 06:00--07:59 ; 08:00--17:59 18:00--21:59 Note : means the temperature control in low temperature condition, generally 7 ℃, it’s in the antifreeze energy-saving state; means in high temperature condition, generally 20 ℃, it’s in a state of normal heating) Copy program 1. Hold “COPY” under main program mode for 3 secs until the COPY symbol display, the week 1 will flashing 2. Press + or - to choose the week you wish to copy 3. Press COPY again and the above selected week stops flashing, then press + or - to arrive at the day that you want to copy to. 4. Then press COPY again to confirm and the changes will be immediately made. 5. Repeat steps 3 to 4 above to copy on different program 6. Press SET to lock in the changes or wait for 15 secs to time out. MANUAL 1. Hold “HOLD” once until the HOLD symbol display, press + or - to set temperature, this settings will running until pressed by SET to quit. 1 2. Hold “HOLD” under main program mode for 3 secs until display d:01 and HOLIDAY symbol, press + or - to adjust from d:01~d:99, set and waiting for 15 secs to automatically confirm; Then press + or - again to set the desired temperature. This setting temperature will running out the setting days to quit or press SET to quit. 3. Press + or - to adjust the setting temperature, then press DAY to lock mode to lock the hours, press + or - to choose the lock hours from 1~9 hrs. Waiting for 15 secs to automatically confirm; This setting temperature will running out the setting hours to quit or press SET to quit. 4. Press + or - to adjust the setting temperature, waiting for 15 secs to automatically confirm; This setting temperature will running until the next PROG or press SET to quit. Backlight Press LIGHT, the backlight will be light on for 15 secs. MODE 1. Press and hold DAY and then…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Ambiance Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Ambiance RF programmable thermostat is a wireless climate control device rated for 6(2)A at 220V, featuring ±1°C temperature accuracy and an adjustable range of 7°C to 35°C. Powered by two AAA 1.5V lithium batteries with 20µA standby current, it suits residential and light commercial HVAC applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Ambiance AMB05004 RF thermostat in the Philippines?

3G Electric Philippines sources the Ambiance AMB05004 thermostat for delivery to Manila, Quezon City, and wider Philippines locations. We handle Bureau of Customs documentation and PHP invoicing. Contact us for availability and pricing.

What is the lead time for the Ambiance AMB05004 thermostat?

Lead time is available on request. 3G Electric manages full import logistics and customs clearance to the Philippines, so total delivery time depends on current stock and regulatory processing. Request a quotation for your timeline.

What temperature range does the Ambiance AMB05004 support?

The Ambiance AMB05004 offers an adjustable temperature range of 7°C to 35°C with ±1°C accuracy at 20°C. Display range is 0°C to 40°C. It runs on two AAA 1.5V lithium batteries with 20µA standby current, ideal for residential and light commercial HVAC applications.

Used in

Common applications for Ambiance
HVAC maintenance and retrofit — Ambiance digital non-programmable thermostats (SKU AMB05010) replace legacy analog controls in plant heating/cooling systems with minimal wiring changes.
Multi-zone building climate control — Ambiance RF programmable thermostat (SKU AMB05004) enables wireless sensor placement in distributed zones without running control conduit across facility ceilings or walls.
Cold-storage and process cooling — Ambiance programmable units maintain tight temperature bands (±1°C accuracy) in pharmaceutical, food-processing, or laboratory environments where setpoint drift triggers alarms or product loss.
Energy-audit and retrofit projects — Ambiance Class IV thermostats reduce standby losses in buildings undergoing efficiency upgrades, providing ErP-compliant controls for certification pathways.
Temporary or modular facility control — Ambiance RF units operate independently on battery power, supporting climate management in portable buildings, temporary production lines, or emergency cooling installations without permanent electrical infrastructure.

Ambiance Products

3G Electric supplies Ambiance climate controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Steel-enclosed remote bulb thermostat with 8 ft capillary and 5 in x 3/8 in bulb. Temperature control range 50° to 130°F, adjustable differential 3.5° to 14°F. SPDT switch action open/close on rise. Operates on 120 to 277V AC. Suitable for indoor single-stage temperature control in HVAC systems, including duct, tank, or space sensing where the controller is mounted remotely from the measured environment
JOHNSON CONTROLS
Steel-enclosed remote bulb thermostat with 8 ft capillary and 5 in x 3/8 in bulb. Temperature control range 50° to 130°F, adjustable differential 3.5° to 14°F. SPDT switch action open/close on rise. Operates on 120 to 277V AC. Suitable for indoor single-stage temperature control in HVAC systems, including duct, tank, or space sensing where the controller is mounted remotely from the measured environment
This low voltage thermostat operates on 19V AC to 30V AC and is field-selectable for BACnet MS/TP or Metasys N2 protocol. It is designed for heat pumps with auxiliary heat or RTUs, featuring an integral humidity sensor and onboard occupancy sensor. The wireless unit supports single or two stage temperature adjustment and includes a USB port for configuration. Housing color is white
JOHNSON CONTROLS
This low voltage thermostat operates on 19V AC to 30V AC and is field-selectable for BACnet MS/TP or Metasys N2 protocol. It is designed for heat pumps with auxiliary heat or RTUs, featuring an integral humidity sensor and onboard occupancy sensor. The wireless unit supports single or two stage temperature adjustment and includes a USB port for configuration. Housing color is white
This thermostat is designed for fan coil units and zoning systems, providing floating/on/off temperature control. It operates on 19V AC to 30V AC and includes a USB port for configuration. The white housing supports wireless connectivity and is compatible with an occupancy sensor. It offers both humidification and dehumidification control, with 1 relay input and 1 relay output
JOHNSON CONTROLS
This thermostat is designed for fan coil units and zoning systems, providing floating/on/off temperature control. It operates on 19V AC to 30V AC and includes a USB port for configuration. The white housing supports wireless connectivity and is compatible with an occupancy sensor. It offers both humidification and dehumidification control, with 1 relay input and 1 relay output
Plastic-enclosed line-voltage mechanical thermostat with hydraulic air coil sensor. SPDT switch with open/close on rise action. Temperature range 30° to 110°F, differential 3° to 12°F. For heat or cool control in HVAC systems
JOHNSON CONTROLS
Plastic-enclosed line-voltage mechanical thermostat with hydraulic air coil sensor. SPDT switch with open/close on rise action. Temperature range 30° to 110°F, differential 3° to 12°F. For heat or cool control in HVAC systems
Steel-enclosed SPST thermostat with close-on-rise action and fixed 2.5°F differential. Temperature control range 30° to 50°F, operates on 24 to 277V AC. Includes 6 ft capillary with 2-5/8 in x 3/8 in bulb. Used for basic temperature regulation in commercial or industrial HVAC applications
JOHNSON CONTROLS
Steel-enclosed SPST thermostat with close-on-rise action and fixed 2.5°F differential. Temperature control range 30° to 50°F, operates on 24 to 277V AC. Includes 6 ft capillary with 2-5/8 in x 3/8 in bulb. Used for basic temperature regulation in commercial or industrial HVAC applications
This thermostat is designed for fan coil units and zoning systems. It operates on 19V AC to 30V AC, features wireless connectivity, and includes a USB port for configuration. The device supports proportional temperature adjustment, is compatible with occupancy sensors, and provides both humidification and dehumidification control. It has 1 relay input and 1 relay output
JOHNSON CONTROLS
This thermostat is designed for fan coil units and zoning systems. It operates on 19V AC to 30V AC, features wireless connectivity, and includes a USB port for configuration. The device supports proportional temperature adjustment, is compatible with occupancy sensors, and provides both humidification and dehumidification control. It has 1 relay input and 1 relay output

More from Ambiance

View all Ambiance parts
Ambiance
Ambiance
ABS gauge axial D50 0/+6bar G1/4
Digital non-programmable room thermostat
Ambiance
Digital non-programmable room thermostat
Programmable thermostat
Ambiance