We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

CANARM Exhaust Fan: 12 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 1,670 cfm - Hazardous Location Shutter-Mount Exhaust Fans
CANARMHazardous Location Shutter-Mount Exhaust Fans

CANARM Exhaust Fan: 12 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 1,670 cfm

The CANARM AX12-4M is a 12-inch hazardous location shutter-mount exhaust fan with a 1/3 hp, 1-speed motor in a totally enclosed air-over enclosure. It delivers 1,670 cfm at 230/460V AC, 3-phase, and is rated for…

SKU 3G-OTH-80182

Also listed as: AX124M · AX12 4M

Brand
CANARM
Item
Exhaust Fan: 12 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 1,670 cfm
Category
Hazardous Location Shutter-Mount Exhaust Fans
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

CANARM
Manufacturer Part Number
AX12-4M
Type
1/3 hp, Totally Enclosed Air Over, 1,670 cfm, 3 ph
AC
230/460V
Speed
1
Frame Finish
Aluminum
Frame Material
Aluminum
Motor Enclosure
Totally Enclosed Air Over
Number of Speeds
1
Nameplate Voltage
230/460V AC
Hazardous Location Class
Class I, Div 1, Group C and D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CANARM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CANARM AX12-4M is a 12-inch hazardous location shutter-mount exhaust fan with a 1/3 hp, 1-speed motor in a totally enclosed air-over enclosure. It delivers 1,670 cfm at 230/460V AC, 3-phase, and is rated for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G. The aluminum frame and finish provide corrosion resistance for demanding industrial environments.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the CANARM AX12-4M exhaust fan used for?

The CANARM AX12-4M is a hazardous location shutter-mount exhaust fan designed for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G environments. It moves 1,670 cfm at 230/460V AC, 3-phase, making it suitable for venting flammable gases, combustible dusts, or corrosive fumes in industrial plants, refineries, and chemical processing facilities.

What are the specifications of the CANARM AX12-4M?

The CANARM AX12-4M has a 12-inch blade, 1/3 hp motor, 1 speed, and delivers 1,670 cfm at 230/460V AC, 3-phase. It features a totally enclosed air-over motor enclosure with an aluminum frame and finish for corrosion resistance. Hazardous location ratings: Class I, Div 1, Groups C and D; Class II, Div 1, Groups F and G.

Where to buy the CANARM AX12-4M worldwide?

3G Electric supplies the CANARM AX12-4M hazardous location exhaust fan to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 1/3 hp, 1,670 cfm, 230/460V AC, 3-phase fan.

How to select a hazardous location exhaust fan like the CANARM AX12-4M?

Select a hazardous location fan by matching its Class, Division, and Group ratings to your area classification. The CANARM AX12-4M is rated Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G. Also verify airflow (1,670 cfm), voltage (230/460V AC, 3-phase), and motor enclosure (totally enclosed air-over) for your application.

Used in

Common applications for CANARM
Warehouse ventilation — CANARM direct-drive panel exhaust fans (e.g., P24-1RS9M115) for removing heat and fumes
Manufacturing plant air circulation — CANARM belt-drive blowers (e.g., BI2731000M) for high-volume air movement
Commercial kitchen exhaust — CANARM downblast exhausters (e.g., ALX165-DD033EC) for roof-mounted ventilation
Industrial floor cooling — CANARM mobile circulating fans (e.g., HVR36) for spot cooling in workshops
Office or retail space ventilation — CANARM wall-mount oscillating fans (e.g., CA30OSC-C) for general air circulation
Equipment cooling — CANARM ceiling-mount fans (e.g., HAF18-ZO) for targeted airflow over machinery

CANARM Products

3G Electric supplies CANARM hazardous location shutter-mount exhaust fans. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MARKEL Hazardous-Location Electric Heater: 3.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-3648-3RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 3.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-3648-3RA)
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 240V AC, 1-phase (MPN FEP-7624-1RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 240V AC, 1-phase (MPN FEP-7624-1RA)
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-7648-3RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-7648-3RA)
SHAT-R-SHIELD Hazardous Light Fixture: 16,000 lm, 5000K, Suspended Mount, T3C/T4 Temp Code, 95 W (MPN 095HY50STFRVLYHZ00SCH701)
SHAT-R-SHIELD
SHAT-R-SHIELD Hazardous Light Fixture: 16,000 lm, 5000K, Suspended Mount, T3C/T4 Temp Code, 95 W (MPN 095HY50STFRVLYHZ00SCH701)
SHAT-R-SHIELD Hazardous Light Fixture: 16,000 lm, 5000K, Yoke/Trunnion Mount, T3C/T4 Temp Code, 95 W (MPN 095HY50STFRVLYHZ00SCH201)
SHAT-R-SHIELD
SHAT-R-SHIELD Hazardous Light Fixture: 16,000 lm, 5000K, Yoke/Trunnion Mount, T3C/T4 Temp Code, 95 W (MPN 095HY50STFRVLYHZ00SCH201)
SHAT-R-SHIELD Hazardous Light Fixture: 3,335 lm, 4000K, 24 W, 120 to 277V AC (MPN 010HY50FLFREMYHZ00SCH001)
SHAT-R-SHIELD
SHAT-R-SHIELD Hazardous Light Fixture: 3,335 lm, 4000K, 24 W, 120 to 277V AC (MPN 010HY50FLFREMYHZ00SCH001)

More from CANARM

View all CANARM parts
Exhaust Fan: 24 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 5,520 cfm, 230/460V AC, 3 ph (MPN AX24-4M)
CANARM
Exhaust Fan: 24 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 5,520 cfm, 230/460V AC, 3 ph (MPN AX24-4M)
Shutter Mounted Hazardous Location Exhaust Fan: 12 in Blade, 1 Speed, 1/3 hp, 1,640 cfm, 115V AC (MPN SD12-XPF)
CANARM
Shutter Mounted Hazardous Location Exhaust Fan: 12 in Blade, 1 Speed, 1/3 hp, 1,640 cfm, 115V AC (MPN SD12-XPF)
Exhaust Fan: 20 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 3,640 cfm, 230/460V AC, 3 ph (MPN AX20-4M)
CANARM
Exhaust Fan: 20 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 3,640 cfm, 230/460V AC, 3 ph (MPN AX20-4M)
Shutter Mounted Hazardous Location Exhaust Fan: 16 in Blade, 1 Speed, 1/3 hp, 2,580 cfm, 1 ph (MPN AX16-4)
CANARM
Shutter Mounted Hazardous Location Exhaust Fan: 16 in Blade, 1 Speed, 1/3 hp, 2,580 cfm, 1 ph (MPN AX16-4)
Shutter Mounted Hazardous Location Exhaust Fan: 14 in Blade, 1 Speed, 1/3 hp, 2,190 cfm, 1 ph (MPN AX14-4)
CANARM
Shutter Mounted Hazardous Location Exhaust Fan: 14 in Blade, 1 Speed, 1/3 hp, 2,190 cfm, 1 ph (MPN AX14-4)
Exhaust Fan: 14 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 2,190 cfm, 230/460V AC, 3 ph (MPN AX14-4M)
CANARM
Exhaust Fan: 14 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 2,190 cfm, 230/460V AC, 3 ph (MPN AX14-4M)
Shutter Mounted Hazardous Location Exhaust Fan: 24 in Blade, 1 Speed, 1/3 hp, 5,520 cfm, 1 ph (MPN AX24-4)
CANARM
Shutter Mounted Hazardous Location Exhaust Fan: 24 in Blade, 1 Speed, 1/3 hp, 5,520 cfm, 1 ph (MPN AX24-4)
Exhaust Fan: 18 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 3,200 cfm, 230/460V AC, 3 ph (MPN AX18-4M)
CANARM
Exhaust Fan: 18 in Blade, 1 Speed, 1/3 hp, Totally Enclosed Air Over, 3,200 cfm, 230/460V AC, 3 ph (MPN AX18-4M)