Datasheet Content
PAR1703-M0 rev 07/08
Air Hydraulic Pumps
Instruction Manual
MODELS: PAR1703, PARD1701, PARD1703, PARM1703
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-891-6599
E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com
! This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Maximum Operating Pressure 10,000 PSI
PAR1703
PARD1701
Printed in Taiwan
Save these instructions. For your safety, read and PRODUCT DESCRIPTION
understand the information contained within. The owner and BVA Rotary Air Hydraulic Pumps provide high volume, high
operator shall have an understanding of this product and safe pressure fluid to compatible applications i.e. rams, presses,
operating procedures before attempting to use this product. spreaders, compactors and crimping machines, anywhere
Instructions and safety information shall be conveyed in that 10,000 PSI of fluid pressure is needed. Special skill,
the operator's native language before use of this product knowledge and training may be required for a specific task
is authorized. Make certain that the operator thoroughly and the product may not be suitable for all the jobs described
understands the inherent dangers associated with the use and above. Unsuitable applications would include applications
misuse of the product. If any doubt exists as to the safe and that call for a device to move, level or support persons,
proper use of this product as outlined in this factory authorized animals, hazardous materials, mobile homes/ dwellings in
manual, remove from service immediately. general, mirrors and/or plate glass, and/or to connect/secure
Inspect before each use. It is recommended that, prior hatches, components, etc. between bulkheads. The user
to each use, an inspection be done by qualified personnel must ultimately make the decision regarding suitability of the
and that any missing or damaged parts, decals, warning/ product for any given task and assume the responsibility of
safety labels or signs be replaced with BVA Hydraulics safety for himself or herself and others in the work area.
authorized replacement parts only. Any pump that appears
to be damaged in any way, is worn, leaking or operates
abnormally shall be removed from service immediately until
such time as repairs can be made. Any pump that has been
or suspected to have been subject to a shock load (a load
dropped suddenly, causing the system pressure to exceed
10,000 PSI), shall be removed from service immediately until To reduce the risk of personal injury and/or property
checked out by a BVA Hydraulics authorized service center.
Owners and operators of this equipment shall be aware that
! damage, ensure that the rated working pressure of
each pressurized attachment be equal to or greater than
the use and subsequent repair of this equipment may require the rated working pressure developed by the hydraulic
special training and knowledge. pump.
Always check connections before using.
Applications may react instantly to the high volume,
! high pressure fluid provided by this pump! Only ! Alteration of these products is strictly prohibited.
competent, skilled and adequately trained individuals shall Use only those adapters and attachments provided and
operate this equipment! approved by the manufacturer.
input air carry handle
direction control valve
lever knob
muffler
dump valve input air
carry handle
muffler
fluid port
reservoir
fluid ports PW3 valve
dump valve
lever
drain plug
drain plug
Figure 1 - Model PAR1703 Components Figure 2 - Model PARD1701 Components
2
! This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
! WARNING
• Study, understand, and follow all • Do not subject the pump and its components to shock
instructions provided with and on this loads.
device before use. • Use only approved accessories and approved hydraulic fluid.
• All WARNING statements must be • Never attach ANY component not authorized by manufacturer.
carefully observed to help prevent • Always ensure that the chosen application is stable to work
personal injury. on and around.
• No alteration shall be made to this • Do not connect to application which can return more oil to
the reservoir than the pump reservoir can hold.
device.
• Do not connect pump to hydraulic system powered by
• Always wear protective gear when
another pump.
operating hydraulic equipment.
• This device is not suitable for use as support device! As
• Keep hydraulic equipment away from
the system load is lifted, use blocking and cribbing to guard
flames and heat. Hydraulic fluid can
against a falling load.
ignite and burn. Do not operate if leaks
• All personnel must be clear before lowering load or
are detected.
depressurizing the system.
• Crush Hazard. Keep hands and feet
• Never try to disassemble a hydraulic cylinder, refer repairs
away from loading area. Avoid pinch
to qualified, authorized personnel.
points or crush points that can be
created by the load, cylinder, or any HYDRAULIC HOSES & FLUID TRANSMISSION LINES
equipment of system. • Avoid short runs of straight line tubing. Straight line runs
• To avoid crushing and related injuries: do not provide for expansion and contraction due to
NEVER work on, under or around pressure and/or temperature changes.
a lifted load before it is properly • Reduce stress in tube lines. Long tubing runs should be
supported by appropriate mechanical supported by brackets or clips. Before operating the pump,
means. Never rely on hydraulic tighten all hose connections with proper tools. Do not
pressure alone to support load. overtighten. Connections should only be tightened securely
and leak-free. Overtightening can cause premature thread
HYDRAULIC PUMPS failure or high pressure fittings to burst.
• The user must be a qualified operator familiar with the • Should a hydraulic hose ever rupture, burst or need to be
correct operation, maintenance, and use of pumps. Lack of disconnected, immediately shut off the pump and release
knowledge in any of these areas can lead to personal injury. all pressure. Never attempt to grasp a leaking pressurized
• Do not exceed rated capacity of the pump or any equipment hose with your hands. The force of escaping hydraulic fluid
in the system. can inflict injury.
• Never attempt to lift a load weighing more than the capacity • Do not subject the hose to potential hazard such as fire,
of the cylinder. sharp objects, extreme heat or cold, or heavy impact.
• Burst hazard exists if hose or connection pressure exceeds • Do not allow the hose to kink, twist, curl, crush, cut or bend
rated pressure. so tightly that the fluid flow within the hose is blocked or
• Inspect pump, cylinder, hoses and connections before each reduced. Periodically inspect the hose for wear.
use to prevent unsafe conditions from developing. Do not • Do not pull, position or move setup by the hose.
use if they are damaged, altered or in poor condition. Do • Hose material and coupler seals must be compatible with
not operate the system with bent or damaged coupler or hydraulic fluid used. Hoses also must not come in contact
damaged threads. with corrosive materials such as battery acid, creosote-
• Never hold or stand directly in line with any hydraulic impregnated objects and wet paint. Never paint a coupler
connections while pressurizing. or hose.
• Use gauge or other load measuring instrument to verify load. • FAILURE TO HEED THESE WARNINGS MAY RESULT
• Never attempt to disconnect hydraulic connections under IN PERSONAL INJURY AS WELL AS PROPERTY
pressure. Release all line…