Datasheet Content
HPD0906-M0_012014
Precision Double
Acting Cylinders
Instruction Manual
MODELS: HPD0906, HPD0910 - 9 Ton capacity
HPD1606, HPD1610 - 16 Ton capacity
SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153
Tel: 888-332-6419 * Fax: 816-891-6599
E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com
Maximum Operating Pressure 10,000 PSI
! This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Printed in Taiwan
SAFETY AND GENERAL INFORMATION ! WARNING: NEVER use hydraulic cylinder as a
support device.
Save these instructions. For your safety, read and understand the
information contained within. The owner and operator shall have an ! WARNING: Always check connections before using.
understanding of this product and safe operating procedures before Alteration of these products is strictly prohibited. Use only
attempting to use this product. Instructions and safety information those adapters and attachments provided and approved by
shall be conveyed in the operator’s native language before use of the manufacturer.
this product is authorized. Make certain that the operator thoroughly WARNING: To reduce the risk of personal injury and/or
understands the inherent dangers associated with the use and
misuse of the product. If any doubt exists as to the safe and proper ! property damage, ensure that the rated working pressure of
each pressurized attachment be equal to or greater than the
use of this product as outlined in this factory authorized manual, rated working pressure developed by the hydraulic pump.
remove from service immediately.
Inspect before each use. Do not use if leaking, broken, bent, BEFORE USE
cracked or otherwise damaged parts are noted. If the cylinder has 1. Before using this product, read the owner's manual completely
been or suspected to have been subjected to a shock load (a load and familiarize yourself thoroughly with the product, its
dropped suddenly, unexpectedly upon it), discontinue use until components and recognize the hazards associated with its use.
checked out by a BVA Hydraulics authorized service center. Owners
2. Verify that the product and the application are compatible. If in
and operators of this equipment shall be aware that the use and
doubt, call BVA Hydraulics Technical Service (888) 332-6419.
subsequent repair of this equipment may require special training
and knowledge. It is recommended that an annual inspection be 3. Inspect before each use. Do not use if bent, broken, leaking or
done by qualified personnel and that any missing or damaged damaged components are noted.
parts, decals, warning/safety labels or signs be replaced with BVA 4. Replace worn or damaged parts and assemblies with BVA
Hydraulics authorized replacement parts only. Any cylinder that Hydraulics authorized replacement parts only. Lubricate as
appears to be damaged in any way, is worn or operates abnormally instructed in Maintenance Section.
shall be removed from service immediately until such time as repairs
can be made. 5. Ensure method of confirming load is accurate and working
properly. Have gauge or load cell accuracy verified by qualified
PRODUCT DESCRIPTION personnel on a yearly basis.
BVA Hydraulics Double Acting Cylinders models HPD0906,
HPD0916, HPD1606 & HPD1610 are designed for rated
capacity pushing, spreading and pressing jobs. A wide variety
of applications exist for this category of product. Special skill,
knowledge and training may be required for a specific task and
the product may not be suitable for all the jobs described above.
Unsuitable applications would include applications that call for
a device to move, level or support persons, animals, hazardous
materials, mobile homes/dwellings in general, mirrors and/or plate
glass, and/or to connect/secure hatches, components, etc. between
bulkheads. The user ultimately must make the decision regarding
suitability of the product for any given task and therefore accept
responsibility for that decision. Immediately after lifting, loads must Ram
be supported by appropriate mechanical means.
Collar
Cylinder
Oil Ports,
3/8” NPTF
Figure 1 - Typical Cylinder Components
2
! WARNING
Failure to comply with the following warnings may not Do not pull, position or move cylinder setup by the
result in personal injury as well as property hose. Use carrying handle or other means of safe
damage. transport.
• Study, understand, and follow all instructions Do not handle pressurized hoses. Never attempt
provided with and on this device before use. to grasp a leaking pressurized hose. Ensure to
release the system pressure before disconnecting
• The user must be a qualified operator familiar hydraulic hose or connections.
with the correct operation, maintenance, and use of
Hydraulic fluid can ignite and burn. Keep hydraulic
cylinders. equipment away from flames and heat. Excessive heat
Wear protective gear when operating will soften seals, resulting in fluid leaks. Heat also
hydraulic equipment. weakens hose materials.
This device is NOT suitable for use as support Cylinder must be on a stable base which is able
device! As the load is lifted, use blocking and to support the load while pushing or lifting. Use shims,
friction material or constrains to prevent slippage of the
cribbing to guard against a falling load. Stay clear
base or load. Ensure cylinder is fully engaged into/
of a lifted load before it is properly supported.
onto adapters, extension accessories.
Never rely on hydraulic pressure to support a load.
Center load on cylinder. Distribute load evenly across
Crush Hazard. Keep hands and feet away the entire saddle surface. Do not off-center loads on
from cylinder and workpiece during a cylinder. The load can tip or the cylinder can “kick
operation. out”.
Both couplers on the cylinder must be connected Never try to disassemble a hydraulic cylinder, refer
to the pump. Double-acting cylinder must be used repairs to qualified, authorized personal. Contact BVA
with a pump equipped with 4-way valve. Hydraulics tech service for authorized service center.
Do not adjust or remove the safety relief valve. Hea
vy Do not subject hose to sharp objects or heavy
Higher setting than rated pressure will result in impact.
equipment damage and/or personal injury. Hose material or seals must not come in contact with
• Do not exceed rated capacity of the cylinder or corrosive materials such as battery acid, creosote-
impregnated objects and wet paint. Never paint a
any equipment in the system. The cylinder is
coupler or hose.
designed for a max. pressure of 10,000 psi.
• No alteration shall be made to the cylinder.
• Do not connect a cylinder to a pump with higher
pressure rating. • Use only factory authorized fasteners, accessories
and hydraulic fluid.
• Do not subject cylinder to a shock loads, a load dropped
suddenly, causing the system pressure to exceed rated Each double acting cylinder is equipped with a
pressure. pressure relief valve in the return circuit which will
open as internal pressure exceeds10K psi.
The system operating pressure must not exceed When this occurs, oil will be directed outside of the cylinder
the pressure rating of the lowest rated component walls and onto the cylinder body. This will create a slippery,
the system. Install a pressure gauge or other hazardous condition in the immediate work area. Clean up…