We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
BELL & GOSSETT Circulating Pump: 115V AC, Cast Iron, Variable, 18 gpm, 20 ft Max. Head - General-Purpose Inline Circulator Pumps
BELL & GOSSETTGeneral-Purpose Inline Circulator Pumps

BELL & GOSSETT Circulating Pump: 115V AC, Cast Iron, Variable, 18 gpm, 20 ft Max. Head

The BELL & GOSSETT ECM Circulating Pump (MPN 60B0B1000) is a general-purpose inline circulator pump designed for potable water systems. This 115V AC unit features a cast iron construction, flange connections, and…

SKU 3G-OTH-83797

Brand
BELL & GOSSETT
Item
Circulating Pump: 115V AC, Cast Iron, Variable, 18 gpm, 20 ft Max. Head
Part Number
60B0B1000
Category
General-Purpose Inline Circulator Pumps
Available to Order
Also known as:60B0B1000BELL & GOSSETT
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

BELL & GOSSETT
Manufacturer Part Number
60B0B1000
Type
Cast Iron, Variable, 18 gpm, 3 3/4 in Face to Face
Max. Head
20 ft
Mfr. Model
60B0B1000
Overall Width
5.9
Overall Height
6.38
Overall Length
4.29
Max. Media Temp.
230
Nameplate Voltage
115V
Flow @ 20' of Head
8
Restricted for Sale
This item is restricted for international sale.
Maximum Feet of Head
20
Minimum Media Temperature
14
Manufacturer Warranty Length
2
For Low Lead Compliance Level
CE
Maximum Flow Rate @ 10 feet of Head
15
Maximum Flow Rate @ 15 feet of Head
12

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BELL & GOSSETT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BELL & GOSSETT ECM Circulating Pump (MPN 60B0B1000) is a general-purpose inline circulator pump designed for potable water systems. This 115V AC unit features a cast iron construction, flange connections, and includes a volute, with a flow rate of 18 gpm and a maximum head of 20 ft, in a 3 3/4 in face-to-face configuration.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the BELL & GOSSETT ECM Circulating Pump used for?

The BELL & GOSSETT ECM Circulating Pump is a general-purpose inline circulator for potable water systems. It moves water in closed-loop hydronic heating or cooling applications, such as residential and commercial building recirculation loops, where variable-speed ECM efficiency and quiet operation are required.

What are the specifications of the BELL & GOSSETT 60B0B1000 pump?

The BELL & GOSSETT 60B0B1000 is a 115V AC, cast iron, variable-speed ECM circulator. It delivers 18 gpm flow with a 20 ft maximum head, has flange connections, includes a volute, and measures 3 3/4 in face to face. It is designed for potable water systems.

Where to buy a BELL & GOSSETT ECM Circulating Pump worldwide?

3G Electric supplies the BELL & GOSSETT ECM Circulating Pump to customers worldwide. As a global industrial sourcing partner, we handle full logistics, customs clearance, and delivery to your site. Contact us for a quote on the 60B0B1000 or other pump models.

How to install a BELL & GOSSETT ECM Circulating Pump?

Install the BELL & GOSSETT ECM Circulating Pump in a horizontal or vertical position with the shaft horizontal. Ensure flange connections are properly aligned and gasketed. Wire the 115V AC supply per local codes. Purge air from the system before startup. Always follow the manufacturer's installation manual.

Used in

Common applications for BELL & GOSSETT
Steam heating systems — Bell & Gossett cast iron F&T steam traps (FT030H-5) for condensate removal in commercial buildings
Hydronic air elimination — Bell & Gossett vertical-discharge air vents (MPN 87) for water systems in HVAC applications
Steam trap maintenance — Bell & Gossett cover gaskets (MPN 405602) and repair kits (MPN 405620) for field servicing of existing traps
Low-pressure steam processes — Bell & Gossett brass offset thermostatic traps (MPN 17C-S-2-25) for condensate drainage in industrial equipment
Replacement of thermostatic elements — Bell & Gossett steam trap elements (MPN 405628) for 17C series traps in process steam lines
Not sure this is the right part? Photo-identify it

BELL & GOSSETT Products

3G Electric supplies BELL & GOSSETT general-purpose inline circulator pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

Compatible alternatives & equivalents

More from BELL & GOSSETT

View all BELL & GOSSETT parts
BELL & GOSSETT
BELL & GOSSETT
This inline circulator pump is designed for hydronic heating and cooling systems. It features a cast iron volute, FNPT connections, and delivers up to 130 gpm at 20 ft maximum head. Suitable for closed-loop applications such as commercial HVAC, boiler systems, and radiant heating

Customer reviews

No reviews yet — be the first

Questions & answers