We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Beckett CG50 Gas Burner 1,400 to 5,000 MBH | AC Power - Gas burners
BeckettGas burners

Beckett CG50 Gas Burner 1,400 to 5,000 MBH | AC Power

Beckett CG50 gas burner delivers 1,400–5,000 MBH firing capacity for commercial heating, steam generation, and industrial food processing applications with advanced combustion control and UV flame detection.

SKU 3G-BKT-00073

Also listed as: CG501S · CG50 1S · CG50-1S

Brand
Beckett
Item
CG50 Gas Burner 1,400 to 5,000 MBH
Category
Gas burners
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Beckett
Motor
2 HP, 3450 RPM
Voltage
208/230V, 1 ph, 60 Hz, 13.4 Amps
Approvals
UL Listed, CSD-1 Configuration
Natural Gas
0.6 Specific Gravity Typical
Propane (LP)
1.53 Specific Gravity Typical
Flame Detection
UV
Firing Rate (US)
730 - 5,000 MBH
Optional Voltages
208/230V 3ph, 460V 3ph, 575V 3ph (60 Hz)
Gas Pressure (Max)
10 PSI
Gas Pressure (Min)
3.5" WC
Optional Approvals
IRI, FM
Controls - High/Low
RM7897C
Firing Rate (Canada)
1,400 - 4,000 MBH
Controls - Modulation
RM7840L
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Beckett Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Beckett CG50 gas burner delivers 1,400–5,000 MBH firing capacity for commercial heating, steam generation, and industrial food processing applications with advanced combustion control and UV flame detection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Beckett CG50 gas burner in the Philippines?

3G Electric Philippines sources the Beckett CG50 for delivery to Manila, Quezon City, and across the region. We handle all Bureau of Customs documentation, logistics, and PHP invoicing. Lead time on request.

What is the lead time for a Beckett CG50 burner order?

Lead time varies based on current availability and your destination within the Philippines. Contact 3G Electric for a specific timeline and delivery quote to your facility.

What fuel types does the Beckett CG50 support?

The CG50 fires natural gas (0.6 SG typical) or propane/LP (1.53 SG typical) at rates from 1,400 to 5,000 MBH. Maximum inlet pressure is 10 PSI; minimum is 3.5 inches water column.

Key Features

  • 2 HP motor, 3450 RPM with 208/230V single-phase power (optional 3-phase and 460V/575V)
  • Firing range: 730–5,000 MBH (US); 1,400–4,000 MBH (Canada)
  • Dual-fuel operation: natural gas and propane with independent specific gravity tuning
  • UV flame detection with direct spark ignition
  • Cast aluminum construction for durability and noise reduction
  • Linkage-free air damper adjustment for simplified commissioning
  • Full modulation capability: accepts 135Ω, 4–20 mA, or 0–10 VAC signals
  • UL/cUL Listed and CSD-1 compliant
  • Quick-disconnect gas gun assembly for rapid service and maintenance
  • Flexible gas train connection: right or left-hand orientation
  • Integrated junction box with terminal strip for faster installation
  • Power On and Fuel On indicator lights standard
  • Optional FM and IRI approvals available
  • Ventless gas train configuration

Used in

Common applications for Beckett
American-spec food-processing boiler burners — AFG scheduled-maintenance parts
Institutional kitchen and cafeteria plant — SF series for 3–7 GPH continuous duty
Commercial gas / dual-fuel — CG10 / CG15 / CG25 for medium-scale installations
Marine and offshore auxiliary plant — Beckett semi-commercial oil burners
Retrofit swap from ageing Italian burners where customer prefers American-style simpler service catalog

Beckett Products

3G Electric supplies Beckett gas burners. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This 1-stage regenerative blower provides oil-free, low-pressure air or vacuum for industrial processes. It delivers a maximum operating pressure of 65 in wc, a maximum vacuum of 60 in wc, and a maximum flow rate of 160 cfm. The unit is driven by a 2 hp three-phase motor rated at 208-230/460V AC, with NPT connections
GAST
This 1-stage regenerative blower provides oil-free, low-pressure air or vacuum for industrial processes. It delivers a maximum operating pressure of 65 in wc, a maximum vacuum of 60 in wc, and a maximum flow rate of 160 cfm. The unit is driven by a 2 hp three-phase motor rated at 208-230/460V AC, with NPT connections
This 1-stage regenerative blower operates on 460V AC three-phase power and delivers a maximum operating pressure of 125 in wc and a maximum vacuum of 115 in wc. It is suitable for continuous-duty industrial applications such as pneumatic conveying, aeration, and vacuum hold-down, providing oil-free air movement
GAST
This 1-stage regenerative blower operates on 460V AC three-phase power and delivers a maximum operating pressure of 125 in wc and a maximum vacuum of 115 in wc. It is suitable for continuous-duty industrial applications such as pneumatic conveying, aeration, and vacuum hold-down, providing oil-free air movement
GAST R6P355A is a 6 hp, 1-stage regenerative blower with a three-phase motor rated for 208-230/460V AC and 16-15/7.5 A. It delivers a maximum operating pressure of 110 in wc and maximum vacuum of 90 in wc, with female NPT connections. Suitable for industrial applications requiring oil-free, low-pressure air or vacuum, such as material handling, wastewater aeration, and pneumatic conveying
GAST
GAST R6P355A is a 6 hp, 1-stage regenerative blower with a three-phase motor rated for 208-230/460V AC and 16-15/7.5 A. It delivers a maximum operating pressure of 110 in wc and maximum vacuum of 90 in wc, with female NPT connections. Suitable for industrial applications requiring oil-free, low-pressure air or vacuum, such as material handling, wastewater aeration, and pneumatic conveying
GAST R6P350A is a 5 hp, 1-stage regenerative blower with a three-phase motor (208-230/460V AC, 12.2-11.2/5.6 A). It delivers 70 in wc maximum operating pressure, 70 in Hg maximum vacuum, and 275 cfm maximum flow rate. Connections are female NPT. Suitable for industrial air movement applications such as material handling, aeration, and pneumatic conveying
GAST
GAST R6P350A is a 5 hp, 1-stage regenerative blower with a three-phase motor (208-230/460V AC, 12.2-11.2/5.6 A). It delivers 70 in wc maximum operating pressure, 70 in Hg maximum vacuum, and 275 cfm maximum flow rate. Connections are female NPT. Suitable for industrial air movement applications such as material handling, aeration, and pneumatic conveying
This GAST 1-stage regenerative blower provides both pressure and vacuum for industrial applications such as pneumatic conveying, aeration, and material handling. It delivers up to 52 in wc pressure, 48 in wc vacuum, and 92 cfm flow. The three-phase motor operates at 208-230/460V AC, 3.4-3.2/1.6 A, with female NPT connections
GAST
This GAST 1-stage regenerative blower provides both pressure and vacuum for industrial applications such as pneumatic conveying, aeration, and material handling. It delivers up to 52 in wc pressure, 48 in wc vacuum, and 92 cfm flow. The three-phase motor operates at 208-230/460V AC, 3.4-3.2/1.6 A, with female NPT connections
This 1-stage regenerative blower from GAST is rated at 10 hp with a three-phase motor (208-230/460V AC, 25.8-24.6/12.3 A). It delivers a maximum operating pressure of 125 in wc and a maximum vacuum of 110 in wc, with female NPT connections. Suitable for industrial air movement applications such as pneumatic conveying, vacuum lifting, and aeration
GAST
This 1-stage regenerative blower from GAST is rated at 10 hp with a three-phase motor (208-230/460V AC, 25.8-24.6/12.3 A). It delivers a maximum operating pressure of 125 in wc and a maximum vacuum of 110 in wc, with female NPT connections. Suitable for industrial air movement applications such as pneumatic conveying, vacuum lifting, and aeration

More from Beckett

View all Beckett parts
Beckett: CG10 Gas Burner 300 to 1,200 MBH | AC Power
Beckett
Beckett: CG10 Gas Burner 300 to 1,200 MBH | AC Power
Beckett: CG4 Gas Burner 80 to 250 MBH | AC Power
Beckett
Beckett: CG4 Gas Burner 80 to 250 MBH | AC Power
Beckett: CG10-24 Gas Burner 300 to 1,200 MBH | AC Power
Beckett
Beckett: CG10-24 Gas Burner 300 to 1,200 MBH | AC Power
Beckett: CG25 Gas Burner 990 to 2,700 MBH | AC Power
Beckett
Beckett: CG25 Gas Burner 990 to 2,700 MBH | AC Power
Beckett: CG15 Gas Burner 560 to 1,500 MBH | AC Power
Beckett
Beckett: CG15 Gas Burner 560 to 1,500 MBH | AC Power