We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K - Thermocouples with Pipe Connection
ASHCROFTThermocouples with Pipe Connection

ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K

The ASHCROFT Thermocouple Probe (SKU 825XZ8, MPN S50DTKN113F2-XU-J7R3-N120LN577) is a Type K thermocouple with pipe connection, offering a temperature range of -328°F to 1,832°F / -200°C to 1,000°C and an accuracy of…

SKU 3G-OTH-201332

Brand
ASHCROFT
Item
Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K
Category
Thermocouples with Pipe Connection
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

ASHCROFT
Manufacturer Part Number
S50DTKN113F2-XU-J7R3-N120LN577
Type
±2.2°C, Type K
Probe Lg
22.72 in
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ASHCROFT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ASHCROFT Thermocouple Probe (SKU 825XZ8, MPN S50DTKN113F2-XU-J7R3-N120LN577) is a Type K thermocouple with pipe connection, offering a temperature range of -328°F to 1,832°F / -200°C to 1,000°C and an accuracy of ±2.2 °C. It features a 22.72-inch probe length.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the ASHCROFT Thermocouple Probe used for?

The ASHCROFT Type K thermocouple probe measures temperatures from -328°F to 1,832°F / -200°C to 1,000°C in industrial processes such as furnaces, exhaust systems, and chemical reactors. Its pipe connection design allows secure installation in pipelines or vessels for continuous temperature monitoring.

What are the specifications of the ASHCROFT Thermocouple Probe?

This ASHCROFT thermocouple probe is Type K with an accuracy of ±2.2 °C. It has a 22.72-inch probe length and operates from -328°F to 1,832°F / -200°C to 1,000°C. The pipe connection enables direct mounting in process lines for reliable temperature sensing.

Where to buy the ASHCROFT Thermocouple Probe worldwide?

3G Electric supplies the ASHCROFT Thermocouple Probe (MPN S50DTKN113F2-XU-J7R3-N120LN577) worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time.

How to install the ASHCROFT Thermocouple Probe?

Install the ASHCROFT thermocouple probe by threading the pipe connection into a compatible process port. Ensure the probe tip reaches the measurement zone. Use appropriate sealing tape or compound on threads. Follow standard thermocouple wiring practices for Type K connections to avoid signal errors.

Used in

Common applications for ASHCROFT
Process control in chemical plants — ASHCROFT G2 series pressure transmitters with 4-20 mA output
Sanitary monitoring in food processing — ASHCROFT sanitary pressure transmitters with stainless steel fittings
Temperature measurement in oil and gas — ASHCROFT flanged thermowells rated to 1,000°F
Hydraulic system pressure monitoring — ASHCROFT G2 series transmitters with 1-5 V DC output
Hazardous location pressure sensing — ASHCROFT A2X explosion-proof transmitters with conduit connection
Steam system temperature protection — ASHCROFT threaded thermowells rated to 7,000 psi

ASHCROFT Products

3G Electric supplies ASHCROFT thermocouples with pipe connection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50DTKN113F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 28.74 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.

More from ASHCROFT

View all ASHCROFT parts
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 28.74 in Probe Lg (MPN S50JTJN111N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 28.74 in Probe Lg (MPN S50JTJN111N2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 28.74 in Probe Lg (MPN S50DTTN111F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 28.74 in Probe Lg (MPN S50DTTN111F2-XU-J7R3-N120LN730). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50STJN111N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50STJN111N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 22.72 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 10.75 in Probe Lg (MPN S50JTKN113N2-XU-J7R3-N120LN273). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -328°F to 1,832°F /-200°C to 1,000°C, ±2.2°C, Type K, 16.73 in Probe Lg (MPN S50STKN113N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50DTJN111F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -40°F to 1,382°F /-40°C to 750°C, ±2.2°C, Type J, 22.72 in Probe Lg (MPN S50DTJN111F2-XU-J7R3-N120LN577). Key specifications — attr1275833: ±2.2 °C; attr1275827: ASHCROFT.
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 16.73 in Probe Lg (MPN S50STTN111N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.
ASHCROFT
ASHCROFT Thermocouple Probe: -418°F to 662°F /-250°C to 350°C, ±1°C, Type T, 16.73 in Probe Lg (MPN S50STTN111N2-XU-J7R3-N120LN425). Key specifications — attr1275833: ±1 °C; attr1275827: ASHCROFT.