We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

APOLLO Atmospheric Vacuum Breaker, 3/4 in, Rough Brass, FNPT x FNPT - Atmospheric Vacuum Breakers
APOLLOAtmospheric Vacuum Breakers

APOLLO Atmospheric Vacuum Breaker, 3/4 in, Rough Brass, FNPT x FNPT

The APOLLO Vacuum Breaker (MPN 3820401) is an atmospheric vacuum breaker with FNPT x FNPT connections, a 3/4 in pipe size, and a rough brass construction for water media. 3G Electric interprets this demand and…

SKU 3G-OTH-597034

Brand
APOLLO
Item
Atmospheric Vacuum Breaker, 3/4 in, Rough Brass, FNPT x FNPT
Category
Atmospheric Vacuum Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

APOLLO
Manufacturer Part Number
3820401
Type
Rough Brass, For Water Media, Brass, Female
Pipe Size
3/4 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

APOLLO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The APOLLO Vacuum Breaker (MPN 3820401) is an atmospheric vacuum breaker with FNPT x FNPT connections, a 3/4 in pipe size, and a rough brass construction for water media. 3G Electric interprets this demand and delivers this genuine industrial part, sourcing it across our 14 departments with specialist depth in controls to support your facility's backflow prevention needs.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is an APOLLO vacuum breaker used for?

An APOLLO vacuum breaker prevents backflow of contaminated water into potable water lines. It is installed on irrigation, boiler, or process water systems to automatically admit air and break the siphon when pressure drops, protecting water quality in industrial and commercial facilities.

What are the specifications of the APOLLO 3820401 vacuum breaker?

The APOLLO 3820401 is an atmospheric vacuum breaker with 3/4 in FNPT x FNPT connections. It is made of rough brass construction for water media. This model is designed for backflow prevention in plumbing and industrial systems where non-hazardous water is used.

Where to buy an APOLLO vacuum breaker worldwide?

3G Electric supplies the genuine APOLLO vacuum breaker MPN 3820401 to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this backflow prevention component.

How to install an APOLLO atmospheric vacuum breaker?

Install the APOLLO vacuum breaker vertically and at least 6 inches above the highest downstream outlet. Ensure the FNPT connections are sealed with PTFE tape and tightened to prevent leaks. Test the assembly for proper air-inlet operation after installation.

Used in

Common applications for APOLLO
Water supply systems — APOLLO double check valve backflow preventers (Series 4A) for backflow protection in commercial buildings.
HVAC piping — APOLLO bronze ball valves (two-piece, FNPT) for shut-off and isolation in heating and cooling loops.
Irrigation networks — APOLLO double check valve assemblies (bronze, FNPT) to prevent contamination of potable water sources.
Process piping — APOLLO three-piece ball valves (full-port, sweat connections) for maintenance-friendly flow control in industrial lines.
Safety systems — APOLLO spring-return lever ball valves (bronze, FNPT) for fail-safe shut-off in fuel or gas applications.
Plumbing repairs — APOLLO repair kits (complete check kits) for servicing backflow preventers in existing installations.

APOLLO Products

3G Electric supplies APOLLO atmospheric vacuum breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from APOLLO

View all APOLLO parts
Atmospheric vacuum breaker for backflow prevention in potable water systems. Constructed of bronze with rough chrome finish, female NPT connections, 3/4 in pipe size. Certified to NSF/ANSI 372 for lead-free compliance. Suitable for irrigation, boiler feed, and process water applications
APOLLO
Atmospheric vacuum breaker for backflow prevention in potable water systems. Constructed of bronze with rough chrome finish, female NPT connections, 3/4 in pipe size. Certified to NSF/ANSI 372 for lead-free compliance. Suitable for irrigation, boiler feed, and process water applications
Atmospheric vacuum breaker for water media, constructed of rough brass and bronze with female NPT connections. Prevents backflow in potable water lines. Pipe size: 3/4 in. Certified to NSF/ANSI 372
APOLLO
Atmospheric vacuum breaker for water media, constructed of rough brass and bronze with female NPT connections. Prevents backflow in potable water lines. Pipe size: 3/4 in. Certified to NSF/ANSI 372
This atmospheric vacuum breaker is constructed with a rough brass and bronze body for water media. It features 2-inch female NPT connections and is certified to NSF/ANSI 372 for lead-free compliance. Used in plumbing systems to prevent back-siphonage of contaminated water into potable supply lines during pressure drops
APOLLO
This atmospheric vacuum breaker is constructed with a rough brass and bronze body for water media. It features 2-inch female NPT connections and is certified to NSF/ANSI 372 for lead-free compliance. Used in plumbing systems to prevent back-siphonage of contaminated water into potable supply lines during pressure drops
Atmospheric vacuum breaker with 1 1/4 in female NPT connections, constructed of rough brass and bronze for water media. Prevents back-siphonage in cross-connection applications such as irrigation and commercial plumbing. Certified to NSF/ANSI 372 for lead-free compliance
APOLLO
Atmospheric vacuum breaker with 1 1/4 in female NPT connections, constructed of rough brass and bronze for water media. Prevents back-siphonage in cross-connection applications such as irrigation and commercial plumbing. Certified to NSF/ANSI 372 for lead-free compliance
Atmospheric vacuum breaker for water media, constructed in rough brass and bronze with female NPT threads. Prevents back-siphonage by venting air during pressure drops. Suitable for irrigation, plumbing, and industrial water lines to protect potable water systems
APOLLO
Atmospheric vacuum breaker for water media, constructed in rough brass and bronze with female NPT threads. Prevents back-siphonage by venting air during pressure drops. Suitable for irrigation, plumbing, and industrial water lines to protect potable water systems
Atmospheric vacuum breaker for water media, constructed of rough brass and bronze with female NPT connections. Prevents back-siphonage in cross-connection applications. Certified to NSF/ANSI 372 for lead-free compliance
APOLLO
Atmospheric vacuum breaker for water media, constructed of rough brass and bronze with female NPT connections. Prevents back-siphonage in cross-connection applications. Certified to NSF/ANSI 372 for lead-free compliance
Atmospheric vacuum breaker for water media, constructed of rough brass with a maximum temperature rating of 212°F. Features 1/4 in FNPT x FNPT connections. Used in plumbing and irrigation systems to prevent back-siphonage and protect potable water from contamination
APOLLO
Atmospheric vacuum breaker for water media, constructed of rough brass with a maximum temperature rating of 212°F. Features 1/4 in FNPT x FNPT connections. Used in plumbing and irrigation systems to prevent back-siphonage and protect potable water from contamination
This atmospheric vacuum breaker is designed for water media to prevent backflow contamination in supply lines. It features a 1 in pipe size with female NPT connections and is constructed from rough brass and bronze. Certified to NSF/ANSI 372 for lead-free compliance
APOLLO
This atmospheric vacuum breaker is designed for water media to prevent backflow contamination in supply lines. It features a 1 in pipe size with female NPT connections and is constructed from rough brass and bronze. Certified to NSF/ANSI 372 for lead-free compliance