We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
AllansonUV Ballasts

Allanson UVB80WHO-120-240V-TAPD UV Ballast – Program Start

3G-OTH-03054 UV BALLASTS – Program Start

SKU 3G-OTH-03054

Also listed as: UVB80WHO120240VTAPD · UVB80WHO 120 240V TAPD

Brand
Allanson
Item
UVB80WHO-120-240V-TAPD UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Size
5.0"x3.0"x1.35"
Lamps
1
Weight
1.10 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
8" to 21"
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
80

Datasheet Content

[{"filename":"3G-OTH-03054.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB80WHO-120-240V-TAPD\n1. Lamp Type\n Lamp Type / Cata # Manufacture Power (W) Current (mA)\n G36T5L/HO/C First Light 75 800\n\n GHO463T5L/4 PIN Light Sources 51 800\n\n GHO275T5L/4 PIN Light Sources 30 800\n\n GHO212T5L/4 PIN Light Sources 23 800\n\n\n\n2. Electrical\nBallast type: Program Start (PS) Efficiency: > 90%\nNumber of lamps: 1 Ballast shut down/protection: EOL/OC\nNormal input voltage: 120-240V, +/- 10%, 50-60 Hz Status indication/alarm: Timer, buzzer, reset\nInput current: 0.66A (120V) / 0.33A(240V) switch, LEDs\nInput current THD: < 10% Ambient temperature: 0 - 40° C\nInput power: 80W @ full load Case maximum temperature: 75° C\nOperating frequency: > 25 kHz Approvals: UL/cUL Listed, Class \"P\",\nLamp current crest factor: 1.7 or less Indoor, Type 1\nPower factor: > 95% Sound rating: “A”\n\n\n\n3. Wiring Diagram 4. Mechanical Data\n\n\n\n\n5. Features\nThe ballast has implemented a microcontroller based timer, as well as alarm buzzer, and diagnostic LEDs for\nmonitoring/sensing both ballast/lamp operation, and lamp life time.\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03054 UV BALLASTS – Program Start

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03054 UV ballast used for?

The Allanson 3G-OTH-03054 is a program-start UV ballast designed to power one high-output UV lamp, such as the G36T5L/HO/C, for water treatment, air purification, or industrial disinfection systems. It operates at 120-240 VAC and delivers 80 W input power.

What are the specifications of the Allanson 3G-OTH-03054?

The Allanson 3G-OTH-03054 is a program-start ballast for one high-output lamp (800 mA). Input voltage is 120-240 VAC ±10%, 50-60 Hz. Input power is 80 W, efficiency >90%, power factor >95%, and operating frequency >25 kHz. It includes EOL/OC protection and diagnostic LEDs.

Where to buy the Allanson 3G-OTH-03054 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03054 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03054 UV ballast?

Mount the Allanson 3G-OTH-03054 in a dry, ventilated area with ambient temperature 0-40°C. Connect input wires to a 120-240 VAC supply per the wiring diagram. Ensure the lamp is compatible (e.g., G36T5L/HO/C). The ballast features a timer, buzzer, and diagnostic LEDs for monitoring.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB80WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB60WHO-120-240V-TADP UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start