We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
AllansonUV Ballasts

Allanson UVB164T6-2100-MV-PD UV Ballast – Program Start – Dimming

3G-OTH-03016 UV BALLAST – Program Start

SKU 3G-OTH-03016

Also listed as: UVB164T62100MVPD · UVB164T6 2100 MV PD

Brand
Allanson
Item
UVB164T6-2100-MV-PD UV Ballast – Program Start – Dimming
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Size
8.5″x 4.0″x 2.75″
Lamps
1
Weight
1.66 lb
Lamp mA
2100
Lamp Type
Amalgam
Input Lamps
1
Lamp Length
36″ to 64″
Potted Case
Ventilated
Input Voltage
120V-240V
Input Wattage
325

Datasheet Content

[{"filename":"UVB164T6-2100-MV-PD_WEB.pdf","text":"Specifications Guide\n UVB Ballasts\nUVB164T6-2100-MV-PD Dimming\n Lamp Type /Catalog # Manufacturer Power (W) Current (A)\n\n NNI 300/147XL Heraeus 325 2.1\n\n\n Amalgam\n TUV 325W XPT Philips 280 2.1\n GIA1564T6LCA/2S13 First Light 260 2\n GPHHA1554T6L Light Sources 320 2.1\n\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power factor: > 95%\nNumber of lamps: 1 Efficiency: > 90%\nNormal input voltage: 120-240V, +/-10%, 50-60 Hz Protection: EOL/OC\nInput current: 2.75A(120V)/1.40A(240V) Low inrush current: 5A\nInput power: 330W @ full load Dimming range: 100% to 50%\nOperating frequency: > 25kHz (output current)\nLamp current crest factor: 1.7 or less Dimming control: 0-10 VDC\nApprovals: UL/cUL Recognized, Sound rating: “A”\n Class “P”, Indoor, Type 1 Weight: 1.66 lbs\n\n\nWiring Diagram and Dimensions\n\n\n\n\n Potentio meter\n Dimming and control (external DC voltage). Red,\n blue diagnostic LEDs, and dry contact for sensing,\n and alarming both ballast/lamp operation, and\n failure.\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3 Canada\n www.allanson.com | cservice@allanson.com | T: 1.800.668.9162 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03016 UV BALLAST – Program Start

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03016 UV ballast used for?

The Allanson 3G-OTH-03016 is a program-start dimming ballast designed to power single amalgam UV lamps, such as the Heraeus NNI 300/147XL or Philips TUV 325W XPT. It is commonly used in water treatment, air purification, and industrial UV curing systems where precise lamp control is required.

What are the specifications of the Allanson 3G-OTH-03016?

This Allanson ballast operates on 120-240 VAC input, delivers 2100 mA to one amalgam lamp, and supports dimming from 100% to 50% via 0-10 VDC control. It measures 8.5" x 4.0" x 2.75", weighs 1.66 lb, and has UL/cUL recognition with Class P, indoor, Type 1 rating.

Where to buy the Allanson 3G-OTH-03016 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03016 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this program-start dimming ballast.

How to install the Allanson 3G-OTH-03016 ballast?

Mount the ballast in a ventilated, indoor location. Connect input power (120-240 VAC) per the wiring diagram. For dimming, connect a 0-10 VDC source to the control terminals. Use the diagnostic LEDs and dry contact for monitoring lamp and ballast status. Always follow local electrical codes.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDP UV Ballast – Program Start – Dimming
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-LP UV Ballast – Program Start – Dimming
Allanson
Allanson
Allanson UVB148T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-1800-MV UV Ballast – Program Start
Allanson
Allanson
Allanson UVB248T6-2200-MV UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start