We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
AllansonHigh Voltage Power Supplies

Allanson AHVPS-48-1-MV High Voltage Power Supply

Our High Voltage Power Supplies convert the 120/240VAC volt, 60 HZ single phase AC supply into the high voltage DC required to power ionizing collection cells. Potential of 8KVDC is required for the Ionizer section…

SKU 3G-OTH-02985

Also listed as: AHVPS481MV · AHVPS 48 1 MV

Brand
Allanson
Item
AHVPS-48-1-MV High Voltage Power Supply
Category
High Voltage Power Supplies
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Dimensions
4.5"x6.25"x1.5"
Input Voltage
120V-240V
Construction Type
PCB
Max Output Current mA
1mA
Max Output Power Wattage
10W
Input Current @ 120V/240V
0.2A/0.1A
Max Output Voltage Ionizer/Collector
8/4KVDC

Datasheet Content

[{"filename":"3G-OTH-02985-High-Voltage-Power-Supply-Spec-Manual-v5.pdf","text":"3G-OTH-02985\n 14kV/40mA High Voltage Power Supply for Electrostatic Air Cleaner\n Specifications and Operating Manual\n\n\n\n 1. General\nThe HV Power Supply (HVPS) must be mounted indoors, protected from weather elements, in a location\neasily accessible by operating service personnel to enable inspection and clean up.\nThe HVPS board is conformal coated however accumulation of dust and lint may result in HV current\nleaks and degraded performance especially in high humidity conditions.\nPlease insure that the HCV power supply compartment is well ventilated by fan to insure air circulation.\n\nThe board must be mounted at least ½” above conductive surface to prevent arcing.\nInsulating pad of the size of the board is highly recommended to be installed below the board.\n\nThe HVPS board is factory adjusted to 8kV. The adjustment range is 7.2 kV to 8.5kV. If necessary the\nHV can be adjusted by trim pot RV1 (labeled HV Adjust). The output current is limited to 1mA. The HV\nsupply output power is limited to ~ 10W. The HVPS board maintains output regulation at no load\ncondition however we do not recommend prolonged operation at no load.\n\nThe HVPS is equipped with universal input, AC/DC power supply and can operate from 120VAC or\n220VAC 50/60HZ power lines.\nThe maximum current draw is 0.2 Amp from 120 VAC line and 0.1 Amp from 220VAC line.\nUse these numbers to select proper wire gage as per applicable standards.\n\nThe HVPS can be also operated from 24 VDC power supply. Consult factory if 24VDC version only (no\nAC power) is preferred.\n\n\n\n\n 2. Field wiring connections\n\nWARNING - RISK OF ELECTRIC SHOCK\n\n\n\n\n 1\n\f These instructions are for qualified personnel only. To reduce the risk of electric shock, do not\nperform any servicing other than contained in the instructions unless you are qualified to do so. All\nwiring must be installed according to national, state and local codes.\n\n\n\n\nFig.2 HV supply connecting points\n\n\nThe HVPS has the following field connections available:\n\n 1. AC power input (quick disconnect terminals)\n 2. 24V DC power input (optional, contact factory))\n 3. HV Connection (+8kV and +4kV quick disconnect terminals)\n 4. HV Status dry contacts\n 5. Bicolor LED indicating HV output status\n\nConnecting points are shown in red in Fig.1 and recommended connections to load cell are shown in\nFig.2.\n\nAC line connections\n\nThe HV power supply requires Live, Neutral and GND connection for safe operation.\n\n 2\n\fConnect Live wire (black) to ”L” terminal and Neutral wire (white) to “N” terminal.\nConnect GND wire (green) to safety Earth GND screw on the chassis.\nConnect “Earth” terminal on the HV supply board to safety Earth GND screw on the chassis.\n\n\n HV Connections\n\nHigh voltage connection is made to quick disconnect terminals labelled +8kV and +4kV.\nConnect the ionizer cable to +8kV terminal and collector cable to +4kV terminal. The HV return current\ncloses through the HV GND terminal.\n\n\n\n HV\n LED GND\n COLLECTOR\n 24VDC\n HV Power Supply\n HV STATUS\n EARTH LOAD CELL\n +4kV\n GND\n AC N AC N\n IONIZER\n AC L AC L +8kV\n\n EARTH\n GND\n Chassis GND\n\n\n\n\nFig.2 Recommended connections to load cell\n\n\n 3. Power – up and verification\n\n 1. Connect bi color LED cable and dry contact cable.\n 2. Connect the load cell, turn power ON. The bicolor LED should turn ON green and dry contacts\n should stay open. Using well insulated HV cable short briefly 8kV to GND and verify that bicolor\n LED turns red and dry contact closes.\n\n\n\n\n 3. Specifications\n\n AC power input\n Voltage range: 100 to 260 VAC 50/60HZ\n 3\n\fMax current draw 0.2 A at 120 V, 0.1A at 220V\n\nDC power input (optional)\nVoltage range: 22 to 24V\nCurrent draw: 0.6 A at max output power (8kV/1mA)\n\nHV output\n8kV at 1mA max\n4kV at 1mA max (the sum of 8kV current and 4 kV current is limited to 1mA)\n\n\nHV status (dry contact, bipolar Opto MOS relay)\nMax continuous current – 50mA\nOperating Voltage - 60V\nIsolation -1500Vrms\nContacts open – HV present\nContacts closed – HV absent (fault)\n\n\n\n\nINDICATORS:\n\n LED Green AC power on, HV is present\n LED Red HV absent (fault)\n\nMechanical Specifications\n\n Dimension of PCB: 4.5” W x 6.25” L x 1.5” H\n\n Weight: 1.1 LB / 0.5kg\n\n\n\nAgency Approvals\n\ncURus, UL 867 Recognized, CE Mark, RoHS Compliance\n\nManufacturer’s marking:\n\nP/N, Date code, serial #, at back side of PCB.\n\n\n\n\n 4"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Our High Voltage Power Supplies convert the 120/240VAC volt, 60 HZ single phase AC supply into the high voltage DC required to power ionizing collection cells. Potential of 8KVDC is required for the Ionizer section and 4KVDC for the collector section of the cells.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-02985 high voltage power supply used for?

The Allanson 3G-OTH-02985 is a high voltage power supply designed for electrostatic air cleaners. It converts 120V-240V AC input into the DC voltages required to power ionizing collection cells, providing 8KVDC for the ionizer section and 4KVDC for the collector section.

What are the specifications of the Allanson 3G-OTH-02985?

The Allanson 3G-OTH-02985 has dimensions of 4.5"x6.25"x1.5", input voltage of 120V-240V, max output current of 1mA, max output power of 10W, and max output voltages of 8KVDC for the ionizer and 4KVDC for the collector. Input current is 0.2A at 120V and 0.1A at 240V.

Where to buy the Allanson 3G-OTH-02985 in Singapore?

3G Electric supplies the Allanson 3G-OTH-02985 high voltage power supply to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this item.

How to install the Allanson 3G-OTH-02985 high voltage power supply?

Mount the Allanson 3G-OTH-02985 indoors in a ventilated compartment, at least ½" above a conductive surface to prevent arcing. Use an insulating pad below the board. Connect Live, Neutral, and GND wires to the quick-disconnect terminals. The unit is factory set to 8kV and can be adjusted via trim pot RV1.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson high voltage power supplies. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson GTO-C-42 High Voltage Cable
Allanson
Allanson GTO-C-42 High Voltage Cable
Allanson GTO-C-18 High Voltage Cable
Allanson
Allanson GTO-C-18 High Voltage Cable
Beckett: Allanson Transformer T92 (120v)
Allanson
Beckett: Allanson Transformer T92 (120v)
Beckett: Allanson Transformer CAT 1092 TYPE F
Allanson
Beckett: Allanson Transformer CAT 1092 TYPE F
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson
Allanson
Allanson 2729-252A Ferromagnetic Transformer

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson AHVPS-714-40-MV High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-12-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-40-MV-PCB High Voltage Power Supply
Allanson
Allanson
Allanson AHVPS-714-06-MV-PCB High Voltage Power Supply