We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Allanson 2260-TW Electronic Ignitor - Electronic Ignitors
AllansonElectronic Ignitors

Allanson 2260-TW Electronic Ignitor

Allanson’s ignitors are designed for constant duty and provide the most reliable ignition source for commercial, residential, and industrial applications.

SKU 3G-OTH-03076

Also listed as: 2260TW · 2260 TW

Brand
Allanson
Item
2260-TW Electronic Ignitor
Category
Electronic Ignitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Allanson
Current
28mA
Grounding
One End Ground
Application
GAS
Hv Terminal
Rajah Connector
Input Voltage
120V
Input Frequency
50/60Hz
Primary Voltage
120 Volt
Secondary Voltage
15.6 kVpk

Datasheet Content

[{"filename":"21-309-SpecSheet-2260_2265-Electric-Ignitors_06.13.2025.pdf","text":"ELECTRONIC IGNITORS\n 2260 / 2265\n\n\n\n\n SPECIFICATION\n SPECIFICATION GUIDE\n DESCRIPTION:\n Allanson’s Electronic Ignitors have proven to be durable,\n effective ignition components that delivers dependable\n power whether your application calls for 120 volts or 230\n volts. The 2260/2265 series are single pole, one end grounded\n models that are versatile, light-weight and compact to meet\n your needs. With four different types to choose from, installa-\n tion on any application will be quick and effortless. These\n energy efficient ignitors are designed for constant duty,\n drawing only ½ an amp and have full wave output.\n\n FEATURES:\n • Easy conversion with mounting tabs and primary\n wire connector\n • No clumsy connections\n • Extended life expectancy and energy efficient\n • Meet requirements for EMI/RFI conditions\n • Quick and easy to install\n • Optional secondary connector kit\n\n Input Supply Frequency (Hz): 50/60\n Secondary Frequency (kHz): >20\n Storage Temperature (degrees °C): -40 to +80\n Operating Temperature (degrees °C): -30 to +40\n Operating Relative Humidity (%): 90\n Loading Air Gap (inches): 1/16 - 1/8\n\n\n TECHNICAL SPECIFICATION: 120 VOLTS\n Pri Sec\nCATALOG # DESCRIPTION mA VA LENGTH DEPTH HEIGHT Wt\n A KVpk\n 2260-TP Mtg tabs / primary plug set with pig tails 3.6 2.5 1.5\n 3G-OTH-03076 Mtg tabs / traditional bottom exit pig tails 3.6 2.6 1.8\n 0.5 15.6 28 72 3/4 lb\n 2260-P Primary wire plug with pig tails set only 3.6 2.5 1.5\n 2260-TWLP Mtg tabs / traditional bottom exit pig tails 3.6 2.6 1.8\n2260-TPLP Mtg tabs / primary plug set with pig tails 0.6 3.78 4 1.75\n2260-TPLPJB Mtg tabs / primary plug set with pig tails, int. junction box 0.6 5.25 4.25 1.75 .85lbs\n\n 230 VOLTS\n Pri Sec\nCATALOG # DESCRIPTION mA VA LENGTH DEPTH HEIGHT Wt\n A KVpk\n2265-TP Mtg tabs / primary plug set with pig tails 3.6 2.5 1.5\n2265-TW Mtg tabs / traditional bottom exit pig tails 3.6 2.6 1.8\n 0.5 15.6 30 72 3/4 lb\n2265-P Primary wire plug with pig tails set only 3.6 2.5 1.5\n2265-TWG Mtg tabs / traditional bottom exit pig tails 3.6 2.6 1.8\n\n\n #21-309\n For more information, please visit us at allanson.com 06.09.25\n\n 83 Commerce Valley Drive E., Markham, ON L3T 7T3 ● 1.800.661.7251 ● cservice@allanson.com\n\f ELECTRONIC IGNITORS\n 2260 / 2265\n\n\n\n\n SPECIFICATION\n SPECIFICATION GUIDE\nDIMENSIONS:\n CAT # SIDE VIEW TOP VIEW\n\n 3.590\n 2260-TP\n 2265-TP 1.500\n2260-TPLP\n .301\n 1.169\n\n .356\n 3.700 2.560 3.200\n 1.169\n\n\n 3G-OTH-03076\n 2265-TW 1.750\n .570\n2260-TWLP .180\n .700\n\n 1.855\n\n\n\n 3.590\n\n\n .301\n 1.169\n 2260-P 1.500\n 2.560\n 2265-P 1.169\n\n\n 5°\n\n 1.855\n\n 2.989\n\n\n\n\n 0.275\n\n\n\n 1.130 1.165\n2260-TPLPJB 1.750 0.358 5.304\n\n\n\n 0.192\n\n\n\n\n 4.148\n 4.690\n\n\n #21-309\n For more information, please visit us at allanson.com 06.09.25\n\n 83 Commerce Valley Drive E., Markham, ON L3T 7T3 ● 1.800.661.7251 ● cservice@allanson.com"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Allanson’s ignitors are designed for constant duty and provide the most reliable ignition source for commercial, residential, and industrial applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Allanson 3G-OTH-03076 Electronic Ignitor used for?

The Allanson 3G-OTH-03076 Electronic Ignitor is used as a reliable ignition source for gas-fired commercial, residential, and industrial burners and appliances. It delivers dependable power for constant-duty applications requiring 120 VAC input and a 15.6 kVpk secondary output.

What are the specifications of the Allanson 3G-OTH-03076 Electronic Ignitor?

The Allanson 3G-OTH-03076 operates on 120 VAC input at 50/60 Hz, draws 28 mA, and produces a secondary voltage of 15.6 kVpk. It is a single-pole, one-end-grounded model with mounting tabs and traditional bottom exit pigtails. Dimensions are 3.6 inches length, 2.6 inches depth, and 1.8 inches height.

Where to buy the Allanson 3G-OTH-03076 Electronic Ignitor in Singapore?

3G Electric supplies the Allanson 3G-OTH-03076 Electronic Ignitor to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this model.

How to install the Allanson 3G-OTH-03076 Electronic Ignitor?

Installation is quick and straightforward using the integrated mounting tabs and primary wire connector. Ensure the ignitor is grounded at one end per the datasheet. Maintain a loading air gap of 1/16 to 1/8 inch between the spark electrode and ground. Always follow the manufacturer's instructions and local codes.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson electronic ignitors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson 2260-TWG Electronic Ignitor
Allanson
Allanson 2260-TWG Electronic Ignitor
Allanson 2260-TP Electronic Ignitor
Allanson
Allanson 2260-TP Electronic Ignitor
Allanson 2260-P Electronic Ignitor
Allanson
Allanson 2260-P Electronic Ignitor
Allanson 2265-TP Electronic Ignitor
Allanson
Allanson 2265-TP Electronic Ignitor
Allanson 2265-P Electronic Ignitor
Allanson
Allanson 2265-P Electronic Ignitor
Allanson 2260-TPLP Electronic Ignitor
Allanson
Allanson 2260-TPLP Electronic Ignitor

More from Allanson

View all Allanson parts
Allanson 2280-653 Electronic Ignitor for Weil Mclain
Allanson
Allanson 2280-653 Electronic Ignitor for Weil Mclain
Allanson 2270-619 Electronic Ignitor for Wayne
Allanson
Allanson 2270-619 Electronic Ignitor for Wayne
Allanson
Allanson
Allanson 2265-TWG Electronic Ignitor
Allanson
Allanson
Allanson 2265-TW Electronic Ignitor
Allanson 2260-TWLP Electronic Ignitor
Allanson
Allanson 2260-TWLP Electronic Ignitor
Allanson
Allanson
Allanson 2275-658 Electronic Ignitor for Beckett
Allanson 2260-TPLPJB Electronic Ignitor
Allanson
Allanson 2260-TPLPJB Electronic Ignitor
Allanson 2275-629 Electronic Ignitor for Carlin
Allanson
Allanson 2275-629 Electronic Ignitor for Carlin