We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

ACME ELECTRIC Drive Isolation Transformer - Drive Isolation Transformers
ACME ELECTRICDrive Isolation Transformers

ACME ELECTRIC Drive Isolation Transformer

The ACME ELECTRIC Isolation Transformer (SKU DTGB0202S, MPN DTGB0202S) is a 20 kVA drive isolation transformer designed for three-phase applications. It operates with a 460V AC input and provides a 266/460V output…

SKU 3G-OTH-44327

Brand
ACME ELECTRIC
Item
Drive Isolation Transformer
Category
Drive Isolation Transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

ACME ELECTRIC
Manufacturer Part Number
DTGB0202S
Type
Three Phase, 266/460V, 3R
AC
460V
Input Voltage
460V AC
Output Voltage
266/460V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ACME ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ACME ELECTRIC Isolation Transformer (SKU DTGB0202S, MPN DTGB0202S) is a 20 kVA drive isolation transformer designed for three-phase applications. It operates with a 460V AC input and provides a 266/460V output, housed in a NEMA 3R enclosure. This unit is engineered to isolate and protect sensitive industrial equipment from electrical noise and transients.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is an ACME ELECTRIC drive isolation transformer used for?

An ACME ELECTRIC drive isolation transformer, such as the 20 kVA DTGB0202S, protects sensitive industrial equipment from electrical noise and transients. It is commonly used in three-phase applications to provide clean, isolated power for variable frequency drives, CNC machines, and other automation systems.

What are the specifications of the ACME ELECTRIC DTGB0202S transformer?

The ACME ELECTRIC DTGB0202S is a 20 kVA three-phase drive isolation transformer with a 460V AC input and a 266/460V output. It features a NEMA 3R enclosure for outdoor or damp indoor use. The manufacturer part number is DTGB0202S, and it is designed to isolate equipment from line disturbances.

Where to buy the ACME ELECTRIC DTGB0202S transformer worldwide?

3G Electric supplies the ACME ELECTRIC DTGB0202S isolation transformer to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 20 kVA, 460V AC unit.

How to select the right ACME ELECTRIC drive isolation transformer?

To select the right ACME ELECTRIC drive isolation transformer, match the kVA rating to your load requirements and verify input/output voltages. For the DTGB0202S, ensure your system is three-phase with a 460V AC input and 266/460V output. Consider the NEMA 3R enclosure for outdoor or washdown environments.

Used in

Common applications for ACME ELECTRIC
Manufacturing plant motor control centers — ACME ELECTRIC DTGA0274S drive isolation transformer for VFD isolation
Outdoor HVAC equipment installations — ACME ELECTRIC DTGB72S transformer with NEMA 3R enclosure for weather resistance
Conveyor system power distribution — ACME ELECTRIC DTGA0142S isolation transformer for noise reduction
Process control panels in industrial facilities — ACME ELECTRIC DTGB0202S transformer for 266/460V output
Pump station variable frequency drives — ACME ELECTRIC DTGA72S transformer for 7.5 kVA load isolation
Automated assembly line machinery — ACME ELECTRIC WSA2 weathershield kit for outdoor transformer protection

ACME ELECTRIC Products

3G Electric supplies ACME ELECTRIC drive isolation transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount. Rated 30 hp, 460V AC at 60 Hz, 3560 RPM, and 35.0 A full load current. Suitable for continuous-duty industrial applications such as pumps, fans, compressors, and conveyors
U.S. MOTORS
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount. Rated 30 hp, 460V AC at 60 Hz, 3560 RPM, and 35.0 A full load current. Suitable for continuous-duty industrial applications such as pumps, fans, compressors, and conveyors
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount for secure installation. Rated 25 hp, 400V AC at 60 Hz, 1180 RPM nameplate speed, and 29.3 A full load current. Suitable for continuous operation in industrial applications such as pumps, fans, compressors, and conveyors
U.S. MOTORS
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount for secure installation. Rated 25 hp, 400V AC at 60 Hz, 1180 RPM nameplate speed, and 29.3 A full load current. Suitable for continuous operation in industrial applications such as pumps, fans, compressors, and conveyors
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount. Rated 30 hp, 400V AC at 60 Hz, 35.0 A full load current, 1775 RPM. Suitable for continuous-duty applications such as pumps, fans, compressors, and conveyors
U.S. MOTORS
Totally enclosed fan-cooled (TEFC) 3-phase AC motor with rigid base and flange mount. Rated 30 hp, 400V AC at 60 Hz, 35.0 A full load current, 1775 RPM. Suitable for continuous-duty applications such as pumps, fans, compressors, and conveyors
Totally enclosed fan cooled (TEFC) 3-phase AC motor rated 10 hp, 575V AC, 1180 RPM, 10.0 A full load current. Rigid base and flange mount for secure installation. Suitable for powering pumps, fans, conveyors, and compressors in industrial environments
U.S. MOTORS
Totally enclosed fan cooled (TEFC) 3-phase AC motor rated 10 hp, 575V AC, 1180 RPM, 10.0 A full load current. Rigid base and flange mount for secure installation. Suitable for powering pumps, fans, conveyors, and compressors in industrial environments
Totally enclosed fan-cooled (TEFC) 3-phase motor rated 3 hp, 460V AC, 3.9 A full load current, and 1770 RPM at 60 Hz. Features a rigid base and flange mount for secure installation in pumps, fans, conveyors, and compressors
U.S. MOTORS
Totally enclosed fan-cooled (TEFC) 3-phase motor rated 3 hp, 460V AC, 3.9 A full load current, and 1770 RPM at 60 Hz. Features a rigid base and flange mount for secure installation in pumps, fans, conveyors, and compressors
This 30 hp, 3-phase AC motor features a totally enclosed fan-cooled (TEFC) enclosure for protection in industrial environments. It operates at 1180 RPM at 60 Hz with a full load current of 35.0 A at 460V AC. The rigid base and flange mount allow secure installation in applications such as pumps, fans, compressors, and conveyors
U.S. MOTORS
This 30 hp, 3-phase AC motor features a totally enclosed fan-cooled (TEFC) enclosure for protection in industrial environments. It operates at 1180 RPM at 60 Hz with a full load current of 35.0 A at 460V AC. The rigid base and flange mount allow secure installation in applications such as pumps, fans, compressors, and conveyors

More from ACME ELECTRIC

View all ACME ELECTRIC parts
Three-phase drive isolation transformer rated 27 kVA. Accepts 460V AC input and provides 133/230V output. Used to electrically isolate variable-frequency drives from power sources in industrial motor control panels, conveyor systems, and pump drives
ACME ELECTRIC
Three-phase drive isolation transformer rated 27 kVA. Accepts 460V AC input and provides 133/230V output. Used to electrically isolate variable-frequency drives from power sources in industrial motor control panels, conveyor systems, and pump drives
Three-phase drive isolation transformer rated 14 kVA. Input voltage 460V AC, output voltage 133/230V AC. Enclosure type NEMA 3R for outdoor or indoor use. Provides electrical isolation for industrial equipment in drive applications
ACME ELECTRIC
Three-phase drive isolation transformer rated 14 kVA. Input voltage 460V AC, output voltage 133/230V AC. Enclosure type NEMA 3R for outdoor or indoor use. Provides electrical isolation for industrial equipment in drive applications
Three-phase drive isolation transformer rated 7.5 kVA. Accepts 460V AC input and delivers 133/230V output. Enclosure rated NEMA 3R for outdoor or indoor use. Provides electrical isolation for drive systems in industrial applications
ACME ELECTRIC
Three-phase drive isolation transformer rated 7.5 kVA. Accepts 460V AC input and delivers 133/230V output. Enclosure rated NEMA 3R for outdoor or indoor use. Provides electrical isolation for drive systems in industrial applications
Three-phase drive isolation transformer with 7.5 kVA rating. Input voltage 460V AC; output voltage 266/460V AC. NEMA 3R enclosure for outdoor or indoor use. Used to isolate motor drives from power sources and reduce electrical noise
ACME ELECTRIC
Three-phase drive isolation transformer with 7.5 kVA rating. Input voltage 460V AC; output voltage 266/460V AC. NEMA 3R enclosure for outdoor or indoor use. Used to isolate motor drives from power sources and reduce electrical noise
Three-phase drive isolation transformer rated 11 kVA. Accepts 460V AC input and provides 266/460V output. NEMA 3R enclosure suitable for indoor or outdoor use. Provides electrical isolation for drive systems in industrial applications
ACME ELECTRIC
Three-phase drive isolation transformer rated 11 kVA. Accepts 460V AC input and provides 266/460V output. NEMA 3R enclosure suitable for indoor or outdoor use. Provides electrical isolation for drive systems in industrial applications
Three-phase drive isolation transformer rated at 27 kVA. Accepts 460V AC input and provides 266/460V output. Used to provide electrical isolation between variable frequency drives and power sources in industrial applications, protecting drive electronics from voltage transients and harmonics
ACME ELECTRIC
Three-phase drive isolation transformer rated at 27 kVA. Accepts 460V AC input and provides 266/460V output. Used to provide electrical isolation between variable frequency drives and power sources in industrial applications, protecting drive electronics from voltage transients and harmonics
Three-phase drive isolation transformer with 14 kVA rating. Input voltage 460V AC, output voltage 266/460V. NEMA 3R enclosure for indoor or outdoor use. Provides electrical isolation for industrial motor drives and variable frequency drives
ACME ELECTRIC
Three-phase drive isolation transformer with 14 kVA rating. Input voltage 460V AC, output voltage 266/460V. NEMA 3R enclosure for indoor or outdoor use. Provides electrical isolation for industrial motor drives and variable frequency drives
Three-phase drive isolation transformer rated 11 kVA. Input 460V AC, output 133/230V. NEMA 3R enclosure for indoor or outdoor use. Provides electrical isolation for industrial equipment such as variable frequency drives and motor control centers
ACME ELECTRIC
Three-phase drive isolation transformer rated 11 kVA. Input 460V AC, output 133/230V. NEMA 3R enclosure for indoor or outdoor use. Provides electrical isolation for industrial equipment such as variable frequency drives and motor control centers