Supplying the Philippines from Singapore. Goods are offered EXW Singapore — collection from our Singapore facility.

3G Electric
TACO VB1016-HY2-FC2A00 General-Purpose Inline Circulator Pump - General-Purpose Inline Circulator Pumps
TACOGeneral-Purpose Inline Circulator Pumps

TACO VB1016-HY2-FC2A00 General-Purpose Inline Circulator Pump

The TACO Hydronic Circulating Pump (MPN VB1016-HY2-FC2A00) is a general-purpose inline circulator pump with a 1/25 hp motor and 120V AC nameplate voltage. It features a cast iron construction, flange connections, and…

SKU 3G-OTH-84663

Also listed as: VB1016HY2FC2A00 · VB1016 HY2 FC2A00

Brand
TACO
Item
VB1016-HY2-FC2A00 General-Purpose Inline Circulator Pump
Part Number
VB1016-HY2-FC2A00
Category
General-Purpose Inline Circulator Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted. Invoices in PHP are paid online through the payment link on the invoice.

Technical Specifications

TACO
Manufacturer Part Number
VB1016-HY2-FC2A00
Type
Cast Iron, Variable, 16 gpm, Inline
AC
120V
Max. Head
10 ft
System Type
Hydronic
Connection Type
Flange
Includes Volute
Volute Included
Nameplate Voltage
120V AC

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

TACO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The TACO Hydronic Circulating Pump (MPN VB1016-HY2-FC2A00) is a general-purpose inline circulator pump with a 1/25 hp motor and 120V AC nameplate voltage. It features a cast iron construction, flange connections, and includes a volute, delivering up to 16 gpm at 10 ft max. head for hydronic systems.

Supplied to the Philippines — compatible with 60 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Manila, Quezon City, Cebu, customs and duties are the buyer's responsibility.

Frequently Asked Questions

What is the TACO VB1016-HY2-FC2A00 hydronic circulating pump used for?

The TACO VB1016-HY2-FC2A00 is a general-purpose inline circulator pump designed for hydronic heating systems. It circulates hot water in residential and commercial closed-loop heating applications, such as radiant floor heating, baseboard radiators, and boiler systems, delivering up to 16 gpm at 10 ft max. head.

What are the specifications of the TACO VB1016-HY2-FC2A00 pump?

The TACO VB1016-HY2-FC2A00 is a 1/25 hp hydronic circulating pump with a 120V AC nameplate voltage. It features cast iron construction, flange connections, and includes a volute. It delivers variable flow up to 16 gpm with a maximum head of 10 ft, suitable for inline installation in hydronic systems.

Where to buy the TACO VB1016-HY2-FC2A00 pump worldwide?

3G Electric supplies the TACO VB1016-HY2-FC2A00 hydronic circulating pump to customers worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this TACO pump.

How to install a TACO hydronic circulating pump?

Install the TACO VB1016-HY2-FC2A00 pump inline with the piping, ensuring the arrow on the volute matches flow direction. Use flange gaskets and bolts for a leak-free connection. Wire the 120V AC motor per local codes, and purge air from the system before startup. Always follow the manufacturer's manual.

Used in

Common applications for TACO
Hydronic heating systems — Taco 49-150T-2 inline air separator removes entrained air to maintain loop efficiency.
Domestic hot water recirculation — Taco HLS-1 under-sink pump reduces wait time at fixtures in residential buildings.
Chilled water cooling loops — Taco SFL-150S isolation flange allows equipment service without system drain.
Circulator pump maintenance — Taco 110-009RP motor coupler restores torque transfer in Series 110 pumps.
Water/glycol systems — Taco 49-200T-2 air separator handles 2 in NPT connections at 150 psi and 240°F.
Commercial hydronic balancing — Taco air separators and isolation flanges support efficient fluid control and serviceability.
Not sure this is the right part? Photo-identify it→

TACO Products

3G Electric supplies TACO general-purpose inline circulator pumps. We supply genuine products and their technical documentation.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

More from TACO

View all TACO parts →
Cast iron inline circulator pump for hydronic heating and cooling systems. Variable-speed motor delivers 16 gpm at 18 ft max head. Flange connections and 115V AC nameplate voltage. Suitable for closed-loop applications such as radiant floor heating, baseboard heating, and chilled water loops
TACO
Cast iron inline circulator pump for hydronic heating and cooling systems. Variable-speed motor delivers 16 gpm at 18 ft max head. Flange connections and 115V AC nameplate voltage. Suitable for closed-loop applications such as radiant floor heating, baseboard heating, and chilled water loops
Cast iron variable speed inline circulator pump for hydronic systems. 230V AC, 44 gpm flow, 26 ft max head. Flange connection, volute included. Suitable for circulating hot water or glycol in closed-loop heating and cooling applications
TACO
Cast iron variable speed inline circulator pump for hydronic systems. 230V AC, 44 gpm flow, 26 ft max head. Flange connection, volute included. Suitable for circulating hot water or glycol in closed-loop heating and cooling applications
Bronze inline circulator pump for potable water systems, rated 115V AC, 7 gpm at 5 ft max. head. Sweat connections with 4 1/4 in face-to-face dimension. Includes volute. Suitable for closed-loop hydronic heating applications
TACO
Bronze inline circulator pump for potable water systems, rated 115V AC, 7 gpm at 5 ft max. head. Sweat connections with 4 1/4 in face-to-face dimension. Includes volute. Suitable for closed-loop hydronic heating applications
General-purpose inline circulator pump for hydronic systems. Stainless steel construction, variable speed, 120 gpm at 65 ft max head. Flange connections, volute included. 200-240V AC, 7/8 hp motor
TACO
General-purpose inline circulator pump for hydronic systems. Stainless steel construction, variable speed, 120 gpm at 65 ft max head. Flange connections, volute included. 200-240V AC, 7/8 hp motor
This general-purpose inline circulator pump is designed for hydronic heating and cooling systems. It features a stainless steel construction, variable-speed operation, and flange connections. The pump delivers 16 gpm at 18 ft max. head and operates on 120V AC. It includes a volute for closed-loop applications such as radiant floor heating and baseboard systems
TACO
This general-purpose inline circulator pump is designed for hydronic heating and cooling systems. It features a stainless steel construction, variable-speed operation, and flange connections. The pump delivers 16 gpm at 18 ft max. head and operates on 120V AC. It includes a volute for closed-loop applications such as radiant floor heating and baseboard systems
This TACO inline circulator pump is designed for hydronic heating systems, circulating water through pipes, radiators, and boilers. It features a cast iron construction, flange connections, and includes a volute. The pump delivers 72 gpm at 25 ft max head with a 10 1/4 in face-to-face dimension and operates on 115V AC
TACO
This TACO inline circulator pump is designed for hydronic heating systems, circulating water through pipes, radiators, and boilers. It features a cast iron construction, flange connections, and includes a volute. The pump delivers 72 gpm at 25 ft max head with a 10 1/4 in face-to-face dimension and operates on 115V AC
This general-purpose inline circulator pump is designed for hydronic heating and cooling systems, circulating water or glycol solutions in closed-loop applications. It operates at 115V AC, delivers 110 gpm, and provides a 15 ft maximum head. The pump features a flange connection, includes a volute, and is constructed with stainless steel
TACO
This general-purpose inline circulator pump is designed for hydronic heating and cooling systems, circulating water or glycol solutions in closed-loop applications. It operates at 115V AC, delivers 110 gpm, and provides a 15 ft maximum head. The pump features a flange connection, includes a volute, and is constructed with stainless steel
This variable-speed inline circulator pump is designed for hydronic systems, moving water or glycol-based fluids in closed-loop applications such as radiant floor heating, baseboard heating, and boiler systems. It delivers up to 16 gpm at 18 ft maximum head, operates on 120V AC, and features union connections with a stainless steel construction and included volute
TACO
This variable-speed inline circulator pump is designed for hydronic systems, moving water or glycol-based fluids in closed-loop applications such as radiant floor heating, baseboard heating, and boiler systems. It delivers up to 16 gpm at 18 ft maximum head, operates on 120V AC, and features union connections with a stainless steel construction and included volute