Supplying the Philippines from Singapore. Goods are offered EXW Singapore — collection from our Singapore facility.

Watts RK 774/774DCDA-CK2 8-12 Backflow Preventer Repair Kit - Repair Kits & Parts for Watts Backflow Preventers
WattsRepair Kits & Parts for Watts Backflow Preventers

Watts RK 774/774DCDA-CK2 8-12 Backflow Preventer Repair Kit

The WATTS Backflow Preventer Repair Kits: First or Second Check Kit (MPN RK 774/774DCDA-CK2 8-12) is a repair kit for Watts backflow preventers. It includes (2) Cam Check with Check O-Rings and is compatible with…

SKU 3G-OTH-436787

Also listed as: RK774774DCDACK2812 · RK 774 774DCDA CK2 8 12 · RK-774-774DCDA-CK2-8-12

Brand
Watts
Item
RK 774/774DCDA-CK2 8-12 Backflow Preventer Repair Kit
Part Number
RK 774/774DCDA-CK2 8-12
Category
Repair Kits & Parts for Watts Backflow Preventers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted. Invoices in PHP are paid online through the payment link on the invoice.

Technical Specifications

Watts
Manufacturer Part Number
RK 774/774DCDA-CK2 8-12
Includes
(2) Cam Check with Check O-Rings
Compatible Valve Size
8 in to 12 in
Compatible With Series
774DCDA
Compatible With Mfr. Model No.
774

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

Watts Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The WATTS Backflow Preventer Repair Kits: First or Second Check Kit (MPN RK 774/774DCDA-CK2 8-12) is a repair kit for Watts backflow preventers. It includes (2) Cam Check with Check O-Rings and is compatible with valve sizes 8 in to 12 in, Series 774DCDA, and Mfr. Model No. 774.

Supplied to the Philippines — compatible with 60 Hz installations. EXW Singapore — collect from our Singapore office (your forwarder may collect); onward freight to Manila, Quezon City, Cebu, customs and duties are the buyer's responsibility.

Frequently Asked Questions

What is the Watts backflow preventer repair kit RK 774/774DCDA-CK2 8-12 used for?

This repair kit is used to replace the first or second check assembly in Watts 774 and 774DCDA series backflow preventers. It is designed for commercial and industrial water systems to maintain backflow protection and prevent contamination of potable water supplies.

What are the specifications of the Watts RK 774/774DCDA-CK2 8-12 repair kit?

The kit includes (2) Cam Check with Check O-Rings. It is compatible with valve sizes 8 in to 12 in, Watts Series 774DCDA, and Mfr. Model No. 774. The manufacturer part number is RK 774/774DCDA-CK2 8-12, and it is compatible with Part No. 774-NRS.

Where to buy Watts backflow preventer repair kits worldwide?

3G Electric supplies Watts backflow preventer repair kits worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on the RK 774/774DCDA-CK2 8-12 kit.

How to install the Watts RK 774/774DCDA-CK2 8-12 check kit?

Installation requires shutting off water supply and depressurizing the system. Remove the old check assembly from the backflow preventer, then install the new cam check and o-rings from the kit. Follow Watts' generic maintenance guidelines for proper torque and testing after installation.

Used in

Common applications for Watts
Boiler systems — Watts ASME Section XIII temperature and pressure relief valves (e.g., F383792) for overpressure protection.
Plumbing systems — Watts water hammer arrestors (e.g., LF15M2-A, 1 LF15M2-C) to absorb pressure surges from quick-closing valves.
Water supply lines — Watts 774-OSY double check backflow preventer for cross-connection control in commercial and industrial facilities.
Instrumentation and fluid handling — Watts polysulfone push-to-connect fittings (e.g., 3524R-141410 reducer tee, 90° elbow adapter) for tool-free tubing connections.
Gas shutoff applications — Watts LFL210-5-M2 non-code temperature and pressure relief valve for automatic gas flow shutoff on high water temperature.
Heating and process systems — Watts copper silicon alloy ASME Section XIII temperature and pressure relief valves for safety relief in hot water and process service.
Not sure this is the right part? Photo-identify it→

Watts Products

3G Electric supplies Watts repair kits & parts for watts backflow preventers. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Repair kit for Watts backflow preventers, compatible with Series RK-774 and Model 774. Includes a cam check with a check O-ring. Fits valve sizes 2-1/2 in to 4 in. Used to replace worn internal components in backflow prevention assemblies
Watts
Repair kit for Watts backflow preventers, compatible with Series RK-774 and Model 774. Includes a cam check with a check O-ring. Fits valve sizes 2-1/2 in to 4 in. Used to replace worn internal components in backflow prevention assemblies
Repair kit for the second check valve assembly in Watts Series 774DCDA and Model 774 backflow preventers. Includes two cam checks with check O-rings. Compatible with 6-inch valve size. Used to maintain backflow protection in commercial water systems
Watts
Repair kit for the second check valve assembly in Watts Series 774DCDA and Model 774 backflow preventers. Includes two cam checks with check O-rings. Compatible with 6-inch valve size. Used to maintain backflow protection in commercial water systems
Watts
Watts
Repair kit for Watts 007 series backflow preventers. Includes cover O-ring. Compatible with 1/2 in valve size and model 007. Used to replace first or second check assembly in potable water systems

More from Watts

View all Watts parts →
This repair kit includes a second check module for Watts backflow preventers. It is compatible with valve sizes 2-1/2 in to 4 in and fits Series 957 and 957RPDA models. Used to restore check-valve function in backflow prevention assemblies
Watts
This repair kit includes a second check module for Watts backflow preventers. It is compatible with valve sizes 2-1/2 in to 4 in and fits Series 957 and 957RPDA models. Used to restore check-valve function in backflow prevention assemblies
Repair kit for Watts 009 series backflow preventers. Includes seat. Compatible with 3/4-inch valve sizes, models 3/4 009M2 and LF009M2. Used to restore relief-valve function in backflow prevention assemblies
Watts
Repair kit for Watts 009 series backflow preventers. Includes seat. Compatible with 3/4-inch valve sizes, models 3/4 009M2 and LF009M2. Used to restore relief-valve function in backflow prevention assemblies
Repair kit for Watts 709 series backflow preventers. Includes disc and spring assembly. Compatible with valve sizes 2-1/2 in to 3 in. Fits models 36JC53, 36JC54, 36JC59, and 36JC60. Used to replace worn check components in backflow preventers for plumbing and irrigation systems
Watts
Repair kit for Watts 709 series backflow preventers. Includes disc and spring assembly. Compatible with valve sizes 2-1/2 in to 3 in. Fits models 36JC53, 36JC54, 36JC59, and 36JC60. Used to replace worn check components in backflow preventers for plumbing and irrigation systems
Relief kit for Watts 009 series backflow preventers, compatible with valve size M2 and models 1-1/4 - 1-1/2 009M2/LF009M2. Includes upper stem O-ring for replacing worn internal components. Used in commercial and industrial water systems to maintain backflow protection
Watts
Relief kit for Watts 009 series backflow preventers, compatible with valve size M2 and models 1-1/4 - 1-1/2 009M2/LF009M2. Includes upper stem O-ring for replacing worn internal components. Used in commercial and industrial water systems to maintain backflow protection
Second check repair kit for Watts 809GC8/809GC9 backflow preventers. Compatible with 1-1/4 in valve size, Series RK-919, and model 1-1/4 LF919-QT-S-FS. Used to restore check-valve function in backflow prevention assemblies for plumbing and irrigation systems
Watts
Second check repair kit for Watts 809GC8/809GC9 backflow preventers. Compatible with 1-1/4 in valve size, Series RK-919, and model 1-1/4 LF919-QT-S-FS. Used to restore check-valve function in backflow prevention assemblies for plumbing and irrigation systems
Bronze test cock with 1/8 in NPT connection, designed as a repair part for Watts Series LF-NPT-TC backflow preventers. Used to connect test equipment for checking system pressure and flow during routine backflow testing in plumbing systems
Watts
Bronze test cock with 1/8 in NPT connection, designed as a repair part for Watts Series LF-NPT-TC backflow preventers. Used to connect test equipment for checking system pressure and flow during routine backflow testing in plumbing systems
Repair kit for Watts 757 and 757DCDA series backflow preventers. Includes red silicone disc elastomer. Compatible with valve sizes 2-1/2 to 4 in. Used to restore check valve function in water systems
Watts
Repair kit for Watts 757 and 757DCDA series backflow preventers. Includes red silicone disc elastomer. Compatible with valve sizes 2-1/2 to 4 in. Used to restore check valve function in water systems
Repair kit for the first check valve assembly in Watts 009 Series backflow preventers. Includes a cover O-ring. Compatible with valve sizes 3/4 in to 1 in, for models 3/4 - 1 009/LF009. Used in commercial and industrial water systems to maintain backflow prevention
Watts
Repair kit for the first check valve assembly in Watts 009 Series backflow preventers. Includes a cover O-ring. Compatible with valve sizes 3/4 in to 1 in, for models 3/4 - 1 009/LF009. Used in commercial and industrial water systems to maintain backflow prevention